Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 8 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,762exploited flaws on CISA’s list
34added in the last 30 days
343new WordPress flaws this week
390,080entries in the database

13 results

  • Sep 29, 2026An improper authorization vulnerability in the end-of-life versions of RTU500’s web application allows an authenticated user to trigger the RTU500 to reboot thrCVE-2026-8067 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 6.5

    An improper authorization vulnerability in the end-of-life versions of RTU500’s web application allows an authenticated user to trigger the RTU500 to reboot through the reset endpoint. Successful exploitation could cause temporary device unavailability and disruption of its intended operation.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 29, 2026A directory traversal vulnerability in the file upload functionality of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to write oCVE-2026-8066 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comCritical 9.1

    A directory traversal vulnerability in the file upload functionality of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to write or overwrite arbitrary files on the device file system. Depending on the files affected, successful exploitation could result in unauthorized modification of device data or disruption of the device’s intended operation.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 29, 2026An authentication bypass vulnerability in the firmware update endpoint of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to uploaCVE-2026-8065 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comCritical 9.1

    An authentication bypass vulnerability in the firmware update endpoint of Hitachi Energy RTU500 end-of-life versions allows an unauthenticated attacker to upload arbitrary firmware through a crafted POST request. Successful exploitation could allow the attacker to modify device functionality or compromise the integrity or availability of the device.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 3, 2026RTU500 has a vulnerability, where high-load scenarios, such as sending GI requests at short intervals, may cause a NULL pointer dereference in the last entry ofCVE-2026-17539 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.9

    RTU500 has a vulnerability, where high-load scenarios, such as sending GI requests at short intervals, may cause a NULL pointer dereference in the last entry of the enhanced message queue. This can cause a BCI_IEC104 fatal write error, resulting in connection interruption and restart, and ultimately a denial of service for bidirectional IEC 60870-5-104 communication.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2026IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable for a NULL pointer dereferencing, if a specially crafted sequence of messages is sent for a cCVE-2026-8479 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 6.9

    IEC 60870-5-104 used in bidirectional mode in RTU500 is vulnerable for a NULL pointer dereferencing, if a specially crafted sequence of messages is sent for a certain time, causing Denial of Service impact. Product is only affected if IEC 60870-5-104 functionality in bidirectional mode (BCI) is configured.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 24, 2026IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame.CVE-2026-1773 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 8.7

    IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 24, 2026RTU500 web interface: An unprivileged user can read user management information.CVE-2026-1772 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.3

    RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 30, 2024A vulnerability exists in the RTU500 that allows for authenticated and authorized users to bypass secure update, if secure update feature was not enabled on aCVE-2024-2617 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.2

    A vulnerability exists in the RTU500 that allows for authenticated and authorized users to bypass secure update, if secure update feature was not enabled on all CMUs of a RTU500. If a malicious actor successfully exploits this vulnerability, they could use it to update the RTU500 with unsigned firmware.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 26, 2024A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below.CVE-2024-1532 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 6.8

    A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could enforce diagnostic texts being displayed as empty strings, if an authorized user uploads a specially crafted stb-language file.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 26, 2024A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below.CVE-2024-1531 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 8.2

    A vulnerability exists in the stb-language file handling that affects the RTU500 series product versions listed below. A malicious actor could print random memory content in the RTU500 system log, if an authorized user uploads a specially crafted stb-language file.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 4, 2024A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above.CVE-2022-2081 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.5

    A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.

    Product
    RTU500 series CMU firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 19, 2023Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below.CVE-2023-6711 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comMedium 5.9

    Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Specially crafted messages sent to the mentioned components are not validated properly and can result in buffer overflow and as final consequence to a reboot of an RTU500 CMU.

    Product
    RTU500 series CMU Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 2, 2022A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above.CVE-2022-28613 · Other software · Hitachi Energy · reported by cybersecurity@hitachienergy.comHigh 7.5

    A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is en-abled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500, causing the receiving RTU500 CMU to reboot. The vulnerability is caused by the validation error in the length information carried in MBAP header in the HCI Modbus TCP function.

    Product
    RTU500 series CMU Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.