Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 12 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,762exploited flaws on CISA’s list
34added in the last 30 days
343new WordPress flaws this week
390,080entries in the database

32 results

  • Oct 30, 2024Delta Electronics InfraSuite Device Master versions prior to 1.0.12 are affected by a deserialization vulnerability that targets the Device-Gateway, which couldCVE-2024-10456 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.3

    Delta Electronics InfraSuite Device Master versions prior to 1.0.12 are affected by a deserialization vulnerability that targets the Device-Gateway, which could allow deserialization of arbitrary .NET objects prior to authentication.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 30, 2023In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a sinCVE-2023-47279 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.5

    In Delta Electronics InfraSuite Device Master v.1.0.7, A vulnerability exists that allows an unauthenticated attacker to disclose user information through a single UDP packet, obtain plaintext credentials, or perform NTLM relaying.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 30, 2023In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute code with local administrator pCVE-2023-47207 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute code with local administrator privileges.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 30, 2023In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, whCVE-2023-46690 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8

    In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an attacker to write to any file to any location of the filesystem, which could lead to remote code execution.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 30, 2023In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a singleCVE-2023-39226 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    In Delta Electronics InfraSuite Device Master v.1.0.7, a vulnerability exists that allows an unauthenticated attacker to execute arbitrary code through a single UDP packet.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 10, 2023​An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file CVE-2023-34316 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govMedium 6.5

    ​An attacker could bypass the latest Delta Electronics InfraSuite Device Master (versions prior to 1.0.7) patch, which could allow an attacker to retrieve file contents.

    Product
    Infrasuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 10, 2023​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management CVE-2023-30765 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8

    ​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contain improper access controls that could allow an attacker to alter privilege management configurations, resulting in privilege escalation.

    Product
    Infrasuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 10, 2023 ​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely exeCVE-2023-34347 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    ​Delta Electronics InfraSuite Device Master versions prior to 1.0.7 contains classes that cannot be deserialized, which could allow an attack to remotely execute arbitrary code.

    Product
    Infrasuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023 Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect serviCVE-2023-1145 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.8

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-DataCollect service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-GatCVE-2023-1144 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contains an improper access control vulnerability in which an attacker can use the Device-Gateway service and bypass authorization, which could result in privilege escalation.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbiCVE-2023-1143 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8

    In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use Lua scripts, which could allow an attacker to remotely execute arbitrary code.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authCVE-2023-1142 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.5

    In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could use URL decoding to retrieve system files, credentials, and bypass authentication resulting in privilege escalation.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary coCVE-2023-1141 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a command injection vulnerability that could allow an attacker to inject arbitrary commands, which could result in remote code execution.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code eCVE-2023-1140 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability that could allow an attacker to achieve unauthenticated remote code execution in the context of an administrator.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which cCVE-2023-1139 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a deserialization vulnerability targeting the Device-gateway service, which could allow deserialization of requests prior to authentication, resulting in remote code execution.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve GCVE-2023-1138 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.5

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain an improper access control vulnerability, which could allow an attacker to retrieve Gateway configuration files to obtain plaintext credentials.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentiaCVE-2023-1137 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govMedium 6.5

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which a low-level user could extract files and plaintext credentials of administrator users, resulting in privilege escalation.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authenticatCVE-2023-1136 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an unauthenticated attacker could generate a valid token, which would lead to authentication bypass.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023 In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which couCVE-2023-1135 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.8

    In Delta Electronics InfraSuite Device Master versions prior to 1.0.5, an attacker could set incorrect directory permissions, which could result in local privilege escalation.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local fCVE-2023-1134 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.1

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 are affected by a path traversal vulnerability, which could allow an attacker to read local files, disclose plaintext credentials, and escalate privileges.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2023Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by defaCVE-2023-1133 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    Delta Electronics InfraSuite Device Master versions prior to 1.0.5 contain a vulnerability in which the Device-status service listens on port 10100/ UDP by default. The service accepts the unverified UDP packets and deserializes the content, which could allow an unauthenticated attacker to remotely execute arbitrary code.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 26, 2023A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a.CVE-2023-0444 · Other software · Deltaww · reported by vulnreport@tenable.comHigh 8.8

    A privilege escalation vulnerability exists in Delta Electronics InfraSuite Device Master 00.00.02a. A default user 'User', which is in the 'Read Only User' group, can view the password of another default user 'Administrator', which is in the 'Administrator' group. This allows any lower privileged user to log in as an administrator.

    Product
    Infrasuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 12, 2023 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port witCVE-2022-41778 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-DataCollect service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification.CVE-2022-41779 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8

    Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allowCVE-2022-41776 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.5

    Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal.CVE-2022-41772 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups.CVE-2022-41688 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operatioCVE-2022-41657 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges.CVE-2022-41644 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8

    Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attaCVE-2022-41629 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.5

    Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication.CVE-2022-40202 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port withoutCVE-2022-38142 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8

    Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.

    Product
    InfraSuite Device Master
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.