17 results

  • Oct 14, 2025A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx.CVE-2025-9068 · Other software · Rockwell Automation · reported by PSIRT@rockwellautomation.comHigh 8.5

    A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initiate a repair and hijack the resulting console window for vbpinstall.exe. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.

    Product
    FactoryTalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 14, 2025A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx.CVE-2025-9067 · Other software · Rockwell Automation · reported by PSIRT@rockwellautomation.comHigh 8.5

    A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. This allows the launching of a command prompt running with SYSTEM-level privileges, allowing full access to all files, processes, and system resources.

    Product
    FactoryTalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 14, 2025A security issue exists within the FactoryTalk Linx Network Browser.CVE-2025-7972 · Other software · Rockwell Automation · reported by PSIRT@rockwellautomation.comHigh 8.4

    A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, and delete FTLinx drivers.

    Product
    FactoryTalk® Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 13, 2023 FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets.CVE-2023-29464 · Other software · Rockwell Automation · reported by PSIRT@rockwellautomation.comHigh 8.2

    FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.

    Product
    FactoryTalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 29, 2020An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll.CVE-2020-5806 · Other software · Rockwellautomation · reported by vulnreport@tenable.comMedium 5.5

    An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 127.0.0.1:7153. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 29, 2020An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCPCVE-2020-5802 · Other software · Rockwellautomation · reported by vulnreport@tenable.comHigh 7.5

    An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resulting in termination of RSLinxNG.exe. Observed in FactoryTalk 6.11. All versions of FactoryTalk Linx are affected.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 29, 2020An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest fCVE-2020-5801 · Other software · Rockwellautomation · reported by vulnreport@tenable.comHigh 7.5

    An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. Observed in FactoryTalk Linx 6.11. All versions of FactoryTalk Linx are affected.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 25, 2020A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior.CVE-2020-27255 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5

    A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the leaking of sensitive information. This information disclosure could lead to the bypass of address space layout randomization (ASLR).

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 25, 2020A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior.CVE-2020-27253 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5

    A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a denial-of-service condition on the device.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 25, 2020A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior.CVE-2020-27251 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govCritical 9.8

    A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code execution.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12005 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5

    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12003 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5

    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12001 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govCritical 9.8

    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-11999 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 8.1

    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 19, 2020Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinCVE-2020-12034 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 8.2

    Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.

    Product
    EDS Subsystem
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 19, 2020Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinCVE-2020-12038 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govMedium 5.5

    Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.

    Product
    EDS Subsystem
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 7, 2018An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized,CVE-2018-10619 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govHigh 7.8

    An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.

    Product
    Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.