Vulnerability database
Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.
22 results
Jun 17, 2024DLL Hijacking vulnerability has been found in CENTUM CAMS Log server provided by Yokogawa Electric Corporation.CVE-2024-5650 · Other software · Yokogawa Electric Corporation · reported by 7168b535-132a-4efe-a076-338f829b2eb9High 8.5
DLL Hijacking vulnerability has been found in CENTUM CAMS Log server provided by Yokogawa Electric Corporation. If an attacker is somehow able to intrude into a computer that installed affected product or access to a shared folder, by replacing the DLL file with a tampered one, it is possible to execute arbitrary programs with the authority of the SYSTEM account. The affected products and versions are as follows: CENTUM CS 3000 R3.08.10 to R3.09.50 CENTUM VP R4.01.00 to R4.03.00, R5.01.00 to R5.04.20, R6.01.00 to R6.11.10.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Mar 11, 2022The following Yokogawa Electric products contain insecure DLL loading issues.CVE-2022-23401 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 7.8
The following Yokogawa Electric products contain insecure DLL loading issues. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Mar 11, 2022CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets.CVE-2022-22729 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.8
CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Mar 11, 2022CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 toCVE-2022-22151 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.1
CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Mar 11, 2022'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration.CVE-2022-22148 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 7.8
'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Mar 11, 2022CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption.CVE-2022-22145 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.1
CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Mar 11, 2022'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration.CVE-2022-22141 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 7.8
'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Mar 11, 2022Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09CVE-2022-21808 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.8
Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Mar 11, 2022There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 CVE-2022-21177 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 8.1
There is a path traversal vulnerability in CAMS for HIS Log Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, andfrom R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordweb-material3.yokogawa.comweb-material3.yokogawa.com
Aug 5, 2020Directory traversal vulnerability in CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, BasiCVE-2020-5609 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpCritical 9.8
Directory traversal vulnerability in CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, Basic) R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote unauthenticated attacker to create or overwrite arbitrary files and run arbitrary commands via unspecified vectors.
- Product
- CAMS for HIS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordjvn.jpweb-material3.yokogawa.com
Aug 5, 2020CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, Basic) R4.01.00 to R6.07.00, B/M9000CS R5CVE-2020-5608 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpCritical 9.8
CAMS for HIS CENTUM CS 3000 (includes CENTUM CS 3000 Small) R3.08.10 to R3.09.50, CENTUM VP (includes CENTUM VP Small, Basic) R4.01.00 to R6.07.00, B/M9000CS R5.04.01 to R5.05.01, and B/M9000 VP R6.01.01 to R8.03.01 allows a remote unauthenticated attacker to bypass authentication and send altered communication packets via unspecified vectors.
- Product
- CAMS for HIS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordjvn.jpweb-material3.yokogawa.com
Feb 5, 2020Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENCVE-2015-5628 · Other software · Yokogawa · reported by vultures@jpcert.or.jpCritical 9.8
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to execute arbitrary code via a crafted packet.
- Product
- CENTUM CS 1000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordyokogawa.comics-cert.us-cert.gov
Feb 5, 2020Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENCVE-2015-5627 · Other software · Yokogawa · reported by vultures@jpcert.or.jpCritical 9.8
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (process outage) via a crafted packet.
- Product
- CENTUM CS 1000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordyokogawa.comics-cert.us-cert.gov
Feb 5, 2020Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENCVE-2015-5626 · Other software · Yokogawa · reported by vultures@jpcert.or.jpCritical 9.8
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (network-communications outage) via a crafted packet.
- Product
- CENTUM CS 1000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordyokogawa.comics-cert.us-cert.gov
Jan 9, 2019Multiple Yokogawa products that contain Vnet/IP Open Communication Driver (CENTUM CS 3000(R3.05.00 - R3.09.50), CENTUM CS 3000 Entry Class(R3.05.00 - R3.09.50),CVE-2018-16196 · Other software · Yokogawa Electric Corporation · reported by vultures@jpcert.or.jpHigh 7.5
Multiple Yokogawa products that contain Vnet/IP Open Communication Driver (CENTUM CS 3000(R3.05.00 - R3.09.50), CENTUM CS 3000 Entry Class(R3.05.00 - R3.09.50), CENTUM VP(R4.01.00 - R6.03.10), CENTUM VP Entry Class(R4.01.00 - R6.03.10), Exaopc(R3.10.00 - R3.75.00), PRM(R2.06.00 - R3.31.00), ProSafe-RS(R1.02.00 - R4.02.00), FAST/TOOLS(R9.02.00 - R10.02.00), B/M9000 VP(R6.03.01 - R8.01.90)) allows remote attackers to cause a denial of service attack that may result in stopping Vnet/IP Open Communication Driver's communication via unspecified vectors.
- Product
- Multiple Yokogawa products that contain Vnet/IP Open Communication Driver
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comjvn.jp
Apr 17, 2018A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CVE-2018-8838 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govMedium 6.5
A weakness in access controls in CENTUM CS 1000 all versions, CENTUM CS 3000 versions R3.09.50 and earlier, CENTUM CS 3000 Small versions R3.09.50 and earlier, CENTUM VP versions R6.03.10 and earlier, CENTUM VP Small versions R6.03.10 and earlier, CENTUM VP Basic versions R6.03.10 and earlier, Exaopc versions R3.75.00 and earlier, B/M9000 CS all versions, and B/M9000 VP versions R8.01.01 and earlier may allow a local attacker to exploit the message management function of the system. A CVSS v3 base score of 6.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:L/I:H/A:H).
- Product
- Yokogawa CENTUM and Exaopc
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Dec 22, 2014BKBCopyD.exe in the Batch Management Packages in Yokogawa CENTUM CS 3000 through R3.09.50 and CENTUM VP through R4.03.00 and R5.x through R5.04.00, and Exaopc tCVE-2014-5208 · Other software · Yokogawa · reported by cret@cert.orgHigh 7.5
BKBCopyD.exe in the Batch Management Packages in Yokogawa CENTUM CS 3000 through R3.09.50 and CENTUM VP through R4.03.00 and R5.x through R5.04.00, and Exaopc through R3.72.10, does not require authentication, which allows remote attackers to read arbitrary files via a RETR operation, write to arbitrary files via a STOR operation, or obtain sensitive database-location information via a PMODE operation, a different vulnerability than CVE-2014-0784.
- Product
- Exaopc
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordyokogawa.comcommunity.rapid7.com
Jul 10, 2014Stack-based buffer overflow in BKFSim_vhfd.exe in Yokogawa CENTUM CS 1000, CENTUM CS 3000 R3.09.50 and earlier, CENTUM VP R5.03.20 and earlier, Exaopc R3.72.00 CVE-2014-3888 · Other software · Yokogawa · reported by vultures@jpcert.or.jpHigh 8.3
Stack-based buffer overflow in BKFSim_vhfd.exe in Yokogawa CENTUM CS 1000, CENTUM CS 3000 R3.09.50 and earlier, CENTUM VP R5.03.20 and earlier, Exaopc R3.72.00 and earlier, B/M9000CS R5.05.01 and earlier, and B/M9000 VP R7.03.01 and earlier, when FCS/Test Function is enabled, allows remote attackers to execute arbitrary code via a crafted packet.
- Product
- Exaopc
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govosvdb.org
May 16, 2014Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier,CVE-2014-0782 · Other software · Yokogawa · reported by ics-cert@hq.dhs.govHigh 8.3
Stack-based buffer overflow in BKESimmgr.exe in the Expanded Test Functions package in Yokogawa CENTUM CS 1000, CENTUM CS 3000 Entry Class R3.09.50 and earlier, CENTUM VP R5.03.00 and earlier, CENTUM VP Entry Class R5.03.00 and earlier, Exaopc R3.71.02 and earlier, B/M9000CS R5.05.01 and earlier, and B/M9000 VP R7.03.01 and earlier allows remote attackers to execute arbitrary code via a crafted packet.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comyokogawa.com
Mar 14, 2014Stack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP CVE-2014-0784 · Other software · Yokogawa · reported by ics-cert@hq.dhs.govHigh 8.3
Stack-based buffer overflow in BKBCopyD.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comyokogawa.com
Mar 14, 2014Stack-based buffer overflow in BKHOdeq.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP pCVE-2014-0783 · Other software · Yokogawa · reported by ics-cert@hq.dhs.govHigh 9
Stack-based buffer overflow in BKHOdeq.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via a crafted TCP packet.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comyokogawa.com
Mar 14, 2014Heap-based buffer overflow in BKCLogSvr.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via crafted UDP paCVE-2014-0781 · Other software · Yokogawa · reported by ics-cert@hq.dhs.govHigh 9.3
Heap-based buffer overflow in BKCLogSvr.exe in Yokogawa CENTUM CS 3000 R3.09.50 and earlier allows remote attackers to execute arbitrary code via crafted UDP packets.
- Product
- CENTUM CS 3000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comyokogawa.com
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.