Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-30030 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportDatabase' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25924)
- Product
- TeleControl Server Basic
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-30003 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectConnections' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25910)
- Product
- TeleControl Server Basic
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-30002 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25909)
- Product
- TeleControl Server Basic
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-29905 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'RestoreFromBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25923)
- Product
- TeleControl Server Basic
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-27540 · Other software · Siemens · reported by productcert@siemens.comCritical 9.3
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'Authenticate' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25913)
- Product
- TeleControl Server Basic
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-27539 · Other software · Siemens · reported by productcert@siemens.comCritical 9.3
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'VerifyUser' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25914)
- Product
- TeleControl Server Basic
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 16, 2025A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2).CVE-2025-27495 · Other software · Siemens · reported by productcert@siemens.comCritical 9.3
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateTrace' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25911)
- Product
- TeleControl Server Basic
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (AlCVE-2025-30280 · Other software · Siemens · reported by productcert@siemens.comMedium 6.9
A vulnerability has been identified in Mendix Runtime V10 (All versions < V10.21.0), Mendix Runtime V10.12 (All versions < V10.12.16), Mendix Runtime V10.18 (All versions < V10.18.5), Mendix Runtime V10.6 (All versions < V10.6.22), Mendix Runtime V8 (All versions < V8.18.35), Mendix Runtime V9 (All versions < V9.24.34). Affected applications allow for entity enumeration due to distinguishable responses in certain client actions. This could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application.
- Product
- Mendix Runtime V10
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3).CVE-2025-30000 · Other software · Siemens · reported by productcert@siemens.comMedium 5.4
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application does not properly restrict permissions of the users. This could allow a lowly-privileged attacker to escalate their privileges.
- Product
- Siemens License Server (SLS)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3).CVE-2025-29999 · Other software · Siemens · reported by productcert@siemens.comMedium 5.4
A vulnerability has been identified in Siemens License Server (SLS) (All versions < V4.3). The affected application searches for executable files in the application folder without proper validation. This could allow an attacker to execute arbitrary code with administrative privileges by placing a malicious executable in the same directory.
- Product
- Siemens License Server (SLS)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), IndustrCVE-2024-54092 · Other software · Siemens · reported by productcert@siemens.comCritical 9.3
A vulnerability has been identified in Industrial Edge Device Kit - arm64 V1.17 (All versions), Industrial Edge Device Kit - arm64 V1.18 (All versions), Industrial Edge Device Kit - arm64 V1.19 (All versions), Industrial Edge Device Kit - arm64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - arm64 V1.21 (All versions < V1.21.1-1), Industrial Edge Device Kit - x86-64 V1.17 (All versions), Industrial Edge Device Kit - x86-64 V1.18 (All versions), Industrial Edge Device Kit - x86-64 V1.19 (All versions), Industrial Edge Device Kit - x86-64 V1.20 (All versions < V1.20.2-1), Industrial Edge Device Kit - x86-64 V1.21 (All versions < V1.21.1-1), Industrial Edge Own Device (IEOD) (All versions < V1.21.1-1-a), Industrial Edge Virtual Device (All versions < V1.21.1-1-a), SCALANCE LPE9413 (6GK5998-3GS01-2AC2) (All versions < V2.1), SIMATIC IPC BX-39A Industrial Edge Device (All versions < V3.0), SIMATIC IPC BX-59A Industrial Edge Device (All versions < V3.0), SIMATIC IPC127E Industrial Edge Device (All versions < V3.0), SIMATIC IPC227E Industrial Edge Device (All versions < V3.0), SIMATIC IPC427E Industrial Edge Device (All versions < V3.0), SIMATIC IPC847E Industrial Edge Devi
- Product
- Industrial Edge Device Kit - arm64 V1.17
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.comcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41796 · Other software · Siemens · reported by productcert@siemens.comMedium 6.9
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices allows to change the login password without knowing the current password. In combination with a prepared CSRF attack (CVE-2024-41795) an unauthenticated attacker could be able to set the password to an attacker-controlled value.
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41795 · Other software · Siemens · reported by productcert@siemens.comMedium 6.9
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices is vulnerable to Cross-Site Request Forgery (CSRF) attacks. This could allow an unauthenticated attacker to change arbitrary device settings by tricking a legitimate device administrator to click on a malicious link.
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41794 · Other software · Siemens · reported by productcert@siemens.comCritical 10
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). Affected devices contain hardcoded credentials for remote access to the device operating system with root privileges. This could allow unauthenticated remote attackers to gain full access to a device, if they are in possession of these credentials and if the ssh service is enabled (e.g., by exploitation of CVE-2024-41793).
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41793 · Other software · Siemens · reported by productcert@siemens.comHigh 7.7
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices provides an endpoint that allows to enable the ssh service without authentication. This could allow an unauthenticated remote attacker to enable remote access to the device via ssh.
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41792 · Other software · Siemens · reported by productcert@siemens.comCritical 9.2
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices contains a path traversal vulnerability. This could allow an unauthenticated attacker it to access arbitrary files on the device with root privileges.
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41791 · Other software · Siemens · reported by productcert@siemens.comMedium 6.9
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not authenticate report creation requests. This could allow an unauthenticated remote attacker to read or clear the log files on the device, reset the device or set the date and time.
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41790 · Other software · Siemens · reported by productcert@siemens.comCritical 9.4
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the region parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41789 · Other software · Siemens · reported by productcert@siemens.comCritical 9.4
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the language parameter in specific POST requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 8, 2025A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions).CVE-2024-41788 · Other software · Siemens · reported by productcert@siemens.comCritical 9.4
A vulnerability has been identified in SENTRON 7KT PAC1260 Data Manager (All versions). The web interface of affected devices does not sanitize the input parameters in specific GET requests. This could allow an authenticated remote attacker to execute arbitrary code with root privileges.
- Product
- SENTRON 7KT PAC1260 Data Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Apr 2, 2025A relative path traversal in Fortinet FortiSIEM versions 7.0.0, 6.7.0 through 6.7.2, 6.6.0 through 6.6.3, 6.5.1, 6.5.0 allows attacker to escalate privilege viaCVE-2023-40714 · Network & remote access · Fortinet · reported by psirt@fortinet.comCritical 9.9
A relative path traversal in Fortinet FortiSIEM versions 7.0.0, 6.7.0 through 6.7.2, 6.6.0 through 6.6.3, 6.5.1, 6.5.0 allows attacker to escalate privilege via uploading certain GUI elements
- Product
- FortiSIEM
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Mar 17, 2025A use of hard-coded cryptographic key vulnerability in FortiSIEM version 5.2.6 may allow a remote unauthenticated attacker to obtain SSH access to the supervisoCVE-2019-17659 · Network & remote access · Fortinet · reported by psirt@fortinet.comLow 3.7
A use of hard-coded cryptographic key vulnerability in FortiSIEM version 5.2.6 may allow a remote unauthenticated attacker to obtain SSH access to the supervisor as the restricted user "tunneluser" by leveraging knowledge of the private key from another installation or a firmware image.
- Product
- FortiSIEM
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordfortiguard.fortinet.com
Mar 13, 2025A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002).CVE-2025-25175 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Simcenter Femap V2401 (All versions < V2401.0003), Simcenter Femap V2406 (All versions < V2406.0002). The affected application contains a memory corruption vulnerability while parsing specially crafted .NEU files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25443)
- Product
- Simcenter Femap V2401
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025An incorrect authorization vulnerability [CWE-863] in FortiSIEM 7.2 all versions, 7.1 all versions, 7.0 all versions, 6.7 all versions, 6.6 all versions, 6.5 alCVE-2024-55592 · Network & remote access · Fortinet · reported by psirt@fortinet.comLow 3.8
An incorrect authorization vulnerability [CWE-863] in FortiSIEM 7.2 all versions, 7.1 all versions, 7.0 all versions, 6.7 all versions, 6.6 all versions, 6.5 all versions, 6.4 all versions, 6.3 all versions, 6.2 all versions, 6.1 all versions, 5.4 all versions, 5.3 all versions, may allow an authenticated attacker to perform unauthorized operations on incidents via crafted HTTP requests.
- Product
- FortiSIEM
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordfortiguard.fortinet.com
Mar 11, 2025An exposure of sensitive information to an unauthorized actor in Fortinet FortiSIEM version 6.7.0 through 6.7.4 and 6.6.0 through 6.6.3 and 6.5.0 through 6.5.1 CVE-2023-40723 · Network & remote access · Fortinet · reported by psirt@fortinet.comHigh 8.1
An exposure of sensitive information to an unauthorized actor in Fortinet FortiSIEM version 6.7.0 through 6.7.4 and 6.6.0 through 6.6.3 and 6.5.0 through 6.5.1 and 6.4.0 through 6.4.2 and 6.3.0 through 6.3.3 and 6.2.0 through 6.2.1 and 6.1.0 through 6.1.2 and 5.4.0 and 5.3.0 through 5.3.3 and 5.2.5 through 5.2.8 and 5.2.1 through 5.2.2 and 5.1.0 through 5.1.3 allows attacker to execute unauthorized code or commands via api request.
- Product
- FortiSIEM
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Mar 11, 2025A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9).CVE-2025-27494 · Other software · Siemens · reported by productcert@siemens.comCritical 9.4
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize input for the pubkey endpoint of the REST API. This could allow an authenticated remote administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.
- Product
- SiPass integrated AC5102 (ACC-G2)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9).CVE-2025-27493 · Other software · Siemens · reported by productcert@siemens.comCritical 9.3
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.9), SiPass integrated ACC-AP (All versions < V6.4.9). Affected devices improperly sanitize user input for specific commands on the telnet command line interface. This could allow an authenticated local administrator to escalate privileges by injecting arbitrary commands that are executed with root privileges.
- Product
- SiPass integrated AC5102 (ACC-G2)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), TCVE-2025-27438 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
- Product
- Teamcenter Visualization V14.3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0).CVE-2025-27398 · Other software · Siemens · reported by productcert@siemens.comLow 2.1
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly neutralize special characters when interpreting user controlled log paths. This could allow an authenticated highly-privileged remote attacker to execute a limited set of binaries that are already present on the filesystem.
- Product
- SCALANCE LPE9403
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0).CVE-2025-27397 · Other software · Siemens · reported by productcert@siemens.comMedium 5.1
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit user controlled paths to which logs are written and from where they are read. This could allow an authenticated highly-privileged remote attacker to read and write arbitrary files in the filesystem, if and only if the malicious path ends with 'log' .
- Product
- SCALANCE LPE9403
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0).CVE-2025-27396 · Other software · Siemens · reported by productcert@siemens.comHigh 8.7
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit the elevation of privileges required to perform certain valid functionality. This could allow an authenticated lowly-privileged remote attacker to escalate their privileges.
- Product
- SCALANCE LPE9403
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0).CVE-2025-27395 · Other software · Siemens · reported by productcert@siemens.comHigh 8.6
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly limit the scope of files accessible through and the privileges of the SFTP functionality. This could allow an authenticated highly-privileged remote attacker to read and write arbitrary files.
- Product
- SCALANCE LPE9403
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0).CVE-2025-27394 · Other software · Siemens · reported by productcert@siemens.comHigh 8.6
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly sanitize user input when creating new SNMP users. This could allow an authenticated highly-privileged remote attacker to execute arbitrary code on the device.
- Product
- SCALANCE LPE9403
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0).CVE-2025-27393 · Other software · Siemens · reported by productcert@siemens.comHigh 8.6
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly sanitize user input when creating new users. This could allow an authenticated highly-privileged remote attacker to execute arbitrary code on the device.
- Product
- SCALANCE LPE9403
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0).CVE-2025-27392 · Other software · Siemens · reported by productcert@siemens.comHigh 8.6
A vulnerability has been identified in SCALANCE LPE9403 (6GK5998-3GS00-2AC2) (All versions < V4.0). Affected devices do not properly sanitize user input when creating new VXLAN configurations. This could allow an authenticated highly-privileged remote attacker to execute arbitrary code on the device.
- Product
- SCALANCE LPE9403
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.00CVE-2025-25267 · Other software · Siemens · reported by productcert@siemens.comMedium 6.9
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict the scope of files accessible to the simulation model. This could allow an unauthorized attacker to compromise the confidentiality of the system.
- Product
- Tecnomatix Plant Simulation V2302
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.00CVE-2025-25266 · Other software · Siemens · reported by productcert@siemens.comHigh 7
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application does not properly restrict access to the file deletion functionality. This could allow an unauthorized attacker to delete files even when access to the system should be prohibited, resulting in potential data loss or unauthorized modification of system files.
- Product
- Tecnomatix Plant Simulation V2302
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), TCVE-2025-23402 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain a use-after-free vulnerability that could be triggered while parsing specially crafted WRL files. An attacker could leverage this vulnerability to execute code in the context of the current process.
- Product
- Teamcenter Visualization V14.3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), TCVE-2025-23401 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
- Product
- Teamcenter Visualization V14.3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), TCVE-2025-23400 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
- Product
- Teamcenter Visualization V14.3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), TCVE-2025-23399 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
- Product
- Teamcenter Visualization V14.3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), TCVE-2025-23398 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
- Product
- Teamcenter Visualization V14.3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), TCVE-2025-23397 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected application is vulnerable to memory corruption while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process.
- Product
- Teamcenter Visualization V14.3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), TCVE-2025-23396 · Other software · Siemens · reported by productcert@siemens.comHigh 7.3
A vulnerability has been identified in Teamcenter Visualization V14.3 (All versions < V14.3.0.13), Teamcenter Visualization V2312 (All versions < V2312.0009), Teamcenter Visualization V2406 (All versions < V2406.0007), Teamcenter Visualization V2412 (All versions < V2412.0002), Tecnomatix Plant Simulation V2302 (All versions < V2302.0021), Tecnomatix Plant Simulation V2404 (All versions < V2404.0010). The affected applications contain an out of bounds write vulnerability when parsing a specially crafted WRL file. This could allow an attacker to execute code in the context of the current process.
- Product
- Teamcenter Visualization V14.3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DACVE-2025-23384 · Other software · Siemens · reported by productcert@siemens.comMedium 6.3
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.2.1), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.2.1), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.2.1), SCALANCE M812-1 ADSL-Router family (All versions < V8.2.1), SCALANCE M816-1 ADSL-Router family (All versions < V8.2.1), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.2.1), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.2.1), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.2.1), SCALANCE M874-3 3G-Router (CN) (6GK5874-3AA00-2FA2) (All versions < V8.2.1), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.2.1), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.2.1), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.2.1), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.2.1), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.2.1), SCALANCE MUB852-1 (A1) (6GK5852-1EA10-1AA1) (All versions < V8.2.1), SCALANCE MUB852-1 (B1) (6GK5852-1EA10-1BA1) (All versions < V8.2.1), SCALANCE MUM853-1 (A1) (6GK5853-2EA10-2AA1) (All versions < V8.2.1), SCALANCE MUM853-1 (B
- Product
- RUGGEDCOM RM1224 LTE(4G) EU
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02).CVE-2024-56336 · Other software · Siemens · reported by productcert@siemens.comCritical 9.5
A vulnerability has been identified in SINAMICS S200 (All versions with serial number beginning with SZVS8, SZVS9, SZVS0 or SZVSN and the FS number is 02). The affected device contains an unlocked bootloader. This security oversight enables attackers to inject malicious code, or install untrusted firmware. The intrinsic security features designed to protect against data manipulation and unauthorized access are compromised when the bootloader is not secured.
- Product
- SINAMICS S200
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC Field PG M6 (All versions < V26.01.12), SIMATIC IPC BX-21A (All versions < V3CVE-2024-56182 · Other software · Siemens · reported by productcert@siemens.comHigh 8.4
A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC Field PG M6 (All versions < V26.01.12), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions < V36.01.03), SIMATIC IPC RC-543B (All versions < V35.01.12), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC RW-543B (All versions < V35.02.10), SIMATIC IPC127E (All versions < V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATIC IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions < V21.01.21), SIMATIC IPC477E (All versions < V21.01.21), SIMATIC IPC477E PRO (All versions < V21.01.21), SIMATIC IPC527
- Product
- SIMATIC Field PG M5
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29CVE-2024-56181 · Other software · Siemens · reported by productcert@siemens.comHigh 8.4
A vulnerability has been identified in SIMATIC Field PG M5 (All versions), SIMATIC IPC BX-21A (All versions < V31.01.07), SIMATIC IPC BX-32A (All versions < V29.01.07), SIMATIC IPC BX-39A (All versions < V29.01.07), SIMATIC IPC BX-59A (All versions < V32.01.04), SIMATIC IPC PX-32A (All versions < V29.01.07), SIMATIC IPC PX-39A (All versions < V29.01.07), SIMATIC IPC PX-39A PRO (All versions < V29.01.07), SIMATIC IPC RC-543A (All versions < V36.01.03), SIMATIC IPC RC-543B (All versions < V35.01.12), SIMATIC IPC RW-543A (All versions < V1.1.4), SIMATIC IPC RW-543B (All versions < V35.02.10), SIMATIC IPC127E (All versions < V27.01.11), SIMATIC IPC227E (All versions), SIMATIC IPC227G (All versions < V28.01.14), SIMATIC IPC277E (All versions), SIMATIC IPC277G (All versions < V28.01.14), SIMATIC IPC277G PRO (All versions < V28.01.14), SIMATIC IPC3000 SMART V3 (All versions), SIMATIC IPC327G (All versions < V28.01.14), SIMATIC IPC347G (All versions), SIMATIC IPC377G (All versions < V28.01.14), SIMATIC IPC427E (All versions < V21.01.21), SIMATIC IPC477E (All versions < V21.01.21), SIMATIC IPC477E PRO (All versions < V21.01.21), SIMATIC IPC527G (All versions), SIMATIC IPC627E (All versions
- Product
- SIMATIC Field PG M5
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Mar 11, 2025A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8).CVE-2024-52285 · Other software · Siemens · reported by productcert@siemens.comMedium 6.9
A vulnerability has been identified in SiPass integrated AC5102 (ACC-G2) (All versions < V6.4.8), SiPass integrated ACC-AP (All versions < V6.4.8). Affected devices expose several MQTT URLs without authentication. This could allow an unauthenticated remote attacker to access sensitive data.
- Product
- SiPass integrated AC5102 (ACC-G2)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert-portal.siemens.com
Feb 14, 2025IBM QRadar SIEM 7.5 is vulnerable to cross-site scripting.CVE-2024-56463 · Other software · IBM · reported by psirt@us.ibm.comMedium 4.8
IBM QRadar SIEM 7.5 is vulnerable to cross-site scripting. This vulnerability allows a privileged user to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session.
- Product
- QRadar SIEM
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.