Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 8 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,764exploited flaws on CISA’s list
35added in the last 30 days
456new WordPress flaws this week
390,714entries in the database

498 results · page 7 of 10

  • May 4, 2020LCDS LAquis SCADA Versions 4.3.1 and prior.CVE-2020-10618 · Other software · Lcds · reported by ics-cert@hq.dhs.govMedium 5.5

    LCDS LAquis SCADA Versions 4.3.1 and prior. The affected product is vulnerable to sensitive information exposure by unauthorized users.

    Product
    Laquis Scada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 29, 2020ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.CVE-2019-5620 · Other software · ABB · reported by cve@rapid7.comCritical 9.8

    ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function.

    Product
    MicroSCADA Pro SYS600
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 15, 2020Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to aCVE-2020-10615 · Other software · Trianglemicroworks · reported by ics-cert@hq.dhs.govHigh 7.5

    Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers cause a denial-of-service condition due to a lack of proper validation of the length of user-supplied data, prior to copying it to a fixed-length stack-based buffer. Authentication is not required to exploit this vulnerability.

    Product
    Scada Data Gateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 15, 2020Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to theCVE-2020-10613 · Other software · Trianglemicroworks · reported by ics-cert@hq.dhs.govHigh 7.5

    Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to disclose sensitive information due to the lack of proper validation of user-supplied data, which can result in a read past the end of an allocated structure. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.

    Product
    Scada Data Gateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 15, 2020Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack ofCVE-2020-10611 · Other software · Trianglemicroworks · reported by ics-cert@hq.dhs.govCritical 9.8

    Triangle MicroWorks SCADA Data Gateway 3.02.0697 through 4.0.122, 2.41.0213 through 4.0.122 allows remote attackers to execute arbitrary code due to the lack of proper validation of user-supplied data, which can result in a type confusion condition. Authentication is not required to exploit this vulnerability. Only applicable to installations using DNP3 Data Sets.

    Product
    Scada Data Gateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 15, 2020A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior.CVE-2020-6992 · Other software · GE · reported by ics-cert@hq.dhs.govMedium 6.7

    A local privilege escalation vulnerability has been identified in the GE Digital CIMPLICITY HMI/SCADA product v10.0 and prior. If exploited, this vulnerability could allow an adversary to modify the system, leading to the arbitrary execution of code. This vulnerability is only exploitable if an attacker has access to an authenticated session. GE Digital CIMPLICITY v11.0, released January 2020, contains mitigation for this local privilege escalation vulnerability. GE Digital recommends all users upgrade to GE CIMPLICITY v11.0 or newer.

    Product
    Cimplicity
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 23, 2020A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a CVE-2020-7479 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 23, 2020A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a CVE-2020-7478 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a remote unauthenticated attacker to read arbitrary files from the IGSS server PC on an unrestricted or shared network when the IGSS Update Service is enabled.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 19, 2020A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versCVE-2020-6970 · Other software · Emerson · reported by ics-cert@hq.dhs.govCritical 9.8

    A Heap-based Buffer Overflow was found in Emerson OpenEnterprise SCADA Server 2.83 (if Modbus or ROC Interfaces have been installed and are in use) and all versions of OpenEnterprise 3.1 through 3.3.3, where a specially crafted script could execute code on the OpenEnterprise Server.

    Product
    OpenEnterprise SCADA Server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 14, 2020The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could resuCVE-2019-13537 · Other software · AVEVA · reported by ics-cert@hq.dhs.govHigh 7.5

    The IEC870IP driver for AVEVA’s Vijeo Citect and Citect SCADA and Schneider Electric’s Power SCADA Operation has a buffer overflow vulnerability that could result in a server-side crash.

    Product
    Vijeo Citect and Citect SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 6, 2020A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 201CVE-2019-6854 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-287: Improper Authentication vulnerability exists in a folder within EcoStruxure Geo SCADA Expert (ClearSCADA) -with initial releases before 1 January 2019- which could cause a low privilege user to delete or modify database, setting or certificate files. Those users must have access to the file system of that operating system to exploit this vulnerability. Affected versions in current support includes ClearSCADA 2017 R3, ClearSCADA 2017 R2, and ClearSCADA 2017.

    Product
    Clearscada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 14, 2019A cross-site scripting (XSS) vulnerability in the login form (/ScadaBR/login.htm) in ScadaBR 1.0CE allows a remote attacker to inject arbitrary web script or HTCVE-2019-16344 · Other software · Scadabr · reported by MITREMedium 6.1

    A cross-site scripting (XSS) vulnerability in the login form (/ScadaBR/login.htm) in ScadaBR 1.0CE allows a remote attacker to inject arbitrary web script or HTML via the username or password parameter.

    Product
    Scadabr
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 15, 2019ScadaBR 1.0CE, and 1.1.x through 1.1.0-RC, has XSS via a request for a nonexistent resource, as demonstrated by the dwr/test/ PATH_INFO.CVE-2019-16321 · Other software · Scadabr · reported by MITREMedium 6.1

    ScadaBR 1.0CE, and 1.1.x through 1.1.0-RC, has XSS via a request for a nonexistent resource, as demonstrated by the dwr/test/ PATH_INFO.

    Product
    Scadabr
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 10, 2019Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.1 allows a remote, unauthenticated attacker to execute arbitrary code via a crafted IOCTL 70603 RPCCVE-2019-3975 · Other software · Advantech · reported by vulnreport@tenable.comCritical 9.8

    Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.1 allows a remote, unauthenticated attacker to execute arbitrary code via a crafted IOCTL 70603 RPC message.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 5, 2019Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive informatCVE-2019-10994 · Other software · Laquisscada · reported by ics-cert@hq.dhs.govLow 3.3

    Processing a specially crafted project file in LAquis SCADA 4.3.1.71 may trigger an out-of-bounds read, which may allow an attacker to obtain sensitive information. The attacker must have local access to the system. A CVSS v3 base score of 2.5 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:N/UI:R/S:U/C:L/I:N/A:N).

    Product
    Scada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 5, 2019A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file.CVE-2019-10980 · Other software · Laquisscada · reported by ics-cert@hq.dhs.govHigh 7.8

    A type confusion vulnerability may be exploited when LAquis SCADA 4.3.1.71 processes a specially crafted project file. This may allow an attacker to execute remote code. The attacker must have local access to the system. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H).

    Product
    Scada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 15, 2019A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when CVE-2019-6827 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-787: Out-of-bounds Write vulnerability exists in Interactive Graphical SCADA System (IGSS), Version 14 and prior, which could cause a software crash when data in the mdb database is manipulated.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 28, 2019In WebAccess/SCADA Versions 8.3.5 and prior, multiple untrusted pointer dereference vulnerabilities may allow a remote attacker to execute arbitrary code.CVE-2019-10993 · Other software · WebAccess · reported by ics-cert@hq.dhs.govCritical 9.8

    In WebAccess/SCADA Versions 8.3.5 and prior, multiple untrusted pointer dereference vulnerabilities may allow a remote attacker to execute arbitrary code.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 28, 2019In WebAccess/SCADA, Versions 8.3.5 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of usCVE-2019-10991 · Other software · WebAccess · reported by ics-cert@hq.dhs.govCritical 9.8

    In WebAccess/SCADA, Versions 8.3.5 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 28, 2019In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of userCVE-2019-10989 · Other software · WebAccess · reported by ics-cert@hq.dhs.govCritical 9.8

    In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 28, 2019In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-suppliCVE-2019-10987 · Other software · WebAccess · reported by ics-cert@hq.dhs.govHigh 8.8

    In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 28, 2019In WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied path prior to use in fiCVE-2019-10985 · Other software · WebAccess · reported by ics-cert@hq.dhs.govCritical 9.1

    In WebAccess/SCADA, Versions 8.3.5 and prior, a path traversal vulnerability is caused by a lack of proper validation of a user-supplied path prior to use in file operations. An attacker can leverage this vulnerability to delete files while posing as an administrator.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 28, 2019In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data.CVE-2019-10983 · Other software · WebAccess · reported by ics-cert@hq.dhs.govHigh 7.5

    In WebAccess/SCADA Versions 8.3.5 and prior, an out-of-bounds read vulnerability is caused by a lack of proper validation of user-supplied data. Exploitation of this vulnerability may allow disclosure of information.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 18, 2019Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 81CVE-2019-3954 · Other software · Advantech · reported by vulnreport@tenable.comCritical 9.8

    Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 81024 RPC call.

    Product
    Webaccess
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 18, 2019Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 10CVE-2019-3953 · Other software · Advantech · reported by vulnreport@tenable.comCritical 9.8

    Stack-based buffer overflow in Advantech WebAccess/SCADA 8.4.0 allows a remote, unauthenticated attacker to execute arbitrary code by sending a crafted IOCTL 10012 RPC call.

    Product
    Webaccess
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 31, 2019In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect usCVE-2019-10981 · Other software · AVEVA · reported by ics-cert@hq.dhs.govHigh 7.8

    In Vijeo Citect 7.30 and 7.40, and CitectSCADA 7.30 and 7.40, a vulnerability has been identified that may allow an authenticated local user access to Citect user credentials.

    Product
    AVEVA Vijeo Citect and CitectSCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 5, 2019Advantech WebAccess/SCADA, Versions 8.3.5 and prior.CVE-2019-6554 · Other software · Advantech · reported by ics-cert@hq.dhs.govHigh 7.5

    Advantech WebAccess/SCADA, Versions 8.3.5 and prior. An improper access control vulnerability may allow an attacker to cause a denial-of-service condition.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 5, 2019Advantech WebAccess/SCADA, Versions 8.3.5 and prior.CVE-2019-6552 · Other software · Advantech · reported by ics-cert@hq.dhs.govCritical 9.8

    Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple command injection vulnerabilities, caused by a lack of proper validation of user-supplied data, may allow remote code execution.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 5, 2019Advantech WebAccess/SCADA, Versions 8.3.5 and prior.CVE-2019-6550 · Other software · Advantech · reported by ics-cert@hq.dhs.govCritical 9.8

    Advantech WebAccess/SCADA, Versions 8.3.5 and prior. Multiple stack-based buffer overflow vulnerabilities, caused by a lack of proper validation of the length of user-supplied data, may allow remote code execution.

    Product
    WebAccess/SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or alloCVE-2018-18994 · Other software · LCDS Laquis · reported by ics-cert@hq.dhs.govHigh 7.1

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows an out of bounds read when opening a specially crafted project file, which may cause a system crash or allow data exfiltration.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 27, 2019Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker toCVE-2019-6536 · Other software · LCDS - Leão Consultoria e Desenvolvimento de Sistemas Ltda ME · reported by ics-cert@hq.dhs.govHigh 7.8

    Opening a specially crafted LCDS LAquis SCADA before 4.3.1.71 ELS file may result in a write past the end of an allocated buffer, which may allow an attacker to execute remote code in the context of the current process.

    Product
    LAquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019WebAccess/SCADA, Version 8.3.CVE-2019-6523 · Other software · Advantech · reported by ics-cert@hq.dhs.govCritical 9.8

    WebAccess/SCADA, Version 8.3. The software does not properly sanitize its inputs for SQL commands.

    Product
    Webaccess/scada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019WebAccess/SCADA, Version 8.3.CVE-2019-6521 · Other software · Advantech · reported by ics-cert@hq.dhs.govHigh 8.6

    WebAccess/SCADA, Version 8.3. Specially crafted requests could allow a possible authentication bypass that could allow an attacker to obtain and manipulate sensitive information.

    Product
    Webaccess/scada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019WebAccess/SCADA, Version 8.3.CVE-2019-6519 · Other software · Advantech · reported by ics-cert@hq.dhs.govCritical 9.8

    WebAccess/SCADA, Version 8.3. An improper authentication vulnerability exists that could allow a possible authentication bypass allowing an attacker to upload malicious data.

    Product
    Webaccess/scada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, whiCVE-2018-19029 · Other software · LCDS · reported by ics-cert@hq.dhs.govHigh 7.8

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remotCVE-2018-19002 · Other software · LCDS · reported by ics-cert@hq.dhs.govHigh 7.8

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.CVE-2018-19000 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govMedium 5.3

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows an authentication bypass, which may allow an attacker access to sensitive data.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.CVE-2018-18998 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govCritical 9.8

    LCDS Laquis SCADA prior to version 4.1.0.4150 uses hard coded credentials, which may allow an attacker unauthorized access to the system with high privileges.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remCVE-2018-18996 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govCritical 9.8

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper authorization or sanitation, which may allow an attacker to execute remote code on the server.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the sCVE-2018-18992 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govHigh 8.8

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows taking in user input without proper sanitation, which may allow an attacker to execute remote code on the server.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation.CVE-2018-18990 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govMedium 5.3

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows a user-supplied path in file operations prior to proper validation. An attacker can leverage this vulnerability to disclose sensitive information under the context of the web server process.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may causeCVE-2018-18986 · Other software · LCDS · reported by ics-cert@hq.dhs.govHigh 7.8

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 1, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration.CVE-2018-19004 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govLow 3.3

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows out of bounds read when opening a specially crafted project file, which may allow data exfiltration.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 1, 2019LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file.CVE-2018-18988 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govHigh 8.8

    LCDS Laquis SCADA prior to version 4.1.0.4150 allows execution of script code by opening a specially crafted report format file. This may allow remote code execution, data exfiltration, or cause a system crash.

    Product
    LCDS Laquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 24, 2018A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core ServicCVE-2018-7793 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.7

    A Credential Management vulnerability exists in FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.) which could cause unauthorized disclosure, modification, or disruption in service when the password is modified without permission.

    Product
    FoxView HMI SCADA (All Foxboro DCS, Foxboro Evo, and IA Series versions prior to Foxboro DCS Control Core Services 9.4 (CCS 9.4) and FoxView 10.5.)
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 23, 2018WellinTech KingSCADA before 3.7.0.0.1 contains a stack-based buffer overflow.CVE-2018-20410 · Other software · Wellintech · reported by MITREHigh 7.5

    WellinTech KingSCADA before 3.7.0.0.1 contains a stack-based buffer overflow. The vulnerability is triggered when sending a specially crafted packet to the AlarmServer (AEserver.exe) service listening on TCP port 12401.

    Product
    Kingscada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 19, 2018WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1.CVE-2018-18999 · Other software · Advantech · reported by ics-cert@hq.dhs.govHigh 7.3

    WebAccess/SCADA, WebAccess/SCADA Version 8.3.2 installed on Windows 2008 R2 SP1. Lack of proper validation of user supplied input may allow an attacker to cause the overflow of a buffer on the stack.

    Product
    Webaccess/scada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 4, 2018Reflected cross-site scripting (non-persistent) in SCADA WebServer (Versions prior to 2.03.0001) could allow an attacker to send a crafted URL that contains JavCVE-2018-18991 · Other software · Spidercontrol · reported by ics-cert@hq.dhs.govMedium 6.1

    Reflected cross-site scripting (non-persistent) in SCADA WebServer (Versions prior to 2.03.0001) could allow an attacker to send a crafted URL that contains JavaScript, which can be reflected off the web application to the victim's browser.

    Product
    Scada Webserver
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 25, 2018Reliance 4 SCADA/HMI, Version 4.7.3 Update 3 and prior.CVE-2018-17904 · Other software · GEOVAP · reported by ics-cert@hq.dhs.govMedium 6.1

    Reliance 4 SCADA/HMI, Version 4.7.3 Update 3 and prior. This vulnerability could allow an unauthorized attacker to inject arbitrary code.

    Product
    Reliance 4 SCADA/HMI
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 16, 2018LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution.CVE-2018-17911 · Other software · LCDS - Leão Consultoria e Desenvolvimento de Sistemas LTDA ME · reported by ics-cert@hq.dhs.govHigh 7.8

    LAquis SCADA Versions 4.1.0.3870 and prior has several stack-based buffer overflow vulnerabilities, which may allow remote code execution.

    Product
    LAquis SCADA
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.