Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 7 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,764exploited flaws on CISA’s list
35added in the last 30 days
477new WordPress flaws this week
390,525entries in the database

462 results · page 6 of 10

  • Jul 20, 2020All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory.CVE-2020-12029 · Other software · Rockwell Automation · reported by ics-cert@hq.dhs.govCritical 9

    All versions of FactoryTalk View SE do not properly validate input of filenames within a project directory. A remote, unauthenticated attacker may be able to execute a crafted file on a remote endpoint that may result in remote code execution (RCE). Rockwell Automation recommends applying patch 1126289. Before installing this patch, the patch rollup dated 06 Apr 2020 or later MUST be applied. 1066644 – Patch Roll-up for CPR9 SRx.

    Product
    FactoryTalk View SE
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 30, 2020A vulnerability in the JPEG image parsing module in DaView Indy, DaVa+, DaOffice softwares could allow an unauthenticated, remote attacker to cause an arbitraryCVE-2020-7816 · Other software · HUMAN TALK · reported by vuln@krcert.or.krHigh 7

    A vulnerability in the JPEG image parsing module in DaView Indy, DaVa+, DaOffice softwares could allow an unauthenticated, remote attacker to cause an arbitrary code execution on an affected device.nThe vulnerability is due to a stack overflow read. An attacker could exploit this vulnerability by sending a crafted PDF file to an affected device.

    Product
    DaView Indy, DaVA+, DaOffice
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 23, 2020In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which couCVE-2020-12033 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 8.8

    In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute remote COM objects with elevated privileges.

    Product
    Factorytalk Services Platform
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12005 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5

    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. A vulnerability exists in the communication function that enables users to upload EDS files by FactoryTalk Linx. This may allow an attacker to upload a file with bad compression, consuming all the available CPU resources, leading to a denial-of-service condition.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12003 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5

    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to use specially crafted requests to traverse the file system and expose sensitive data on the local hard drive.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-12001 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govCritical 9.8

    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. The parsing mechanism that processes certain file types does not provide input sanitation. This may allow an attacker to use specially crafted files to traverse the file system and modify or expose sensitive data or execute arbitrary code.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 15, 2020FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14CVE-2020-11999 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 8.1

    FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryTalk Asset Centre: Version 9 and later, FactoryTalk Linx CommDTM: Version 1 and later, Studio 5000 Launcher: Version 31 and later Stud, 5000 Logix Designer software: Version 32 and prior is vulnerable. An exposed API call allows users to provide files to be processed without sanitation. This may allow an attacker to specify a filename to execute unauthorized code and modify files or data.

    Product
    Factorytalk Linx
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 8, 2020A too lax check in Nextcloud Talk 6.0.4, 7.0.2 and 8.0.7 allowed a code injection when a not correctly sanitized talk command was added by an administrator.CVE-2020-8180 · Other software · Nextcloud · reported by support@hackerone.comCritical 9.9

    A too lax check in Nextcloud Talk 6.0.4, 7.0.2 and 8.0.7 allowed a code injection when a not correctly sanitized talk command was added by an administrator.

    Product
    Talk
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 19, 2020Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinCVE-2020-12034 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 8.2

    Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions.

    Product
    EDS Subsystem
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 19, 2020Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinCVE-2020-12038 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govMedium 5.5

    Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions.

    Product
    EDS Subsystem
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 23, 2020In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NECVE-2020-6967 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govCritical 9.8

    In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082, which can insecurely deserialize untrusted data.

    Product
    Factorytalk Services Platform
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 4, 2020Improper access control in Nextcloud Talk 6.0.3 leaks the existance and the name of private conversations when linked them to another shared item via the projecCVE-2019-15620 · Other software · Nextcloud · reported by support@hackerone.comLow 2.7

    Improper access control in Nextcloud Talk 6.0.3 leaks the existance and the name of private conversations when linked them to another shared item via the projects feature.

    Product
    Talk
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 4, 2020Improper neutralization of file names, conversation names and board names in Nextcloud Server 16.0.3, Nextcloud Talk 6.0.3 and Nextcloud Deck 0.6.5 causes an XSCVE-2019-15619 · Other software · Nextcloud · reported by support@hackerone.comMedium 4.8

    Improper neutralization of file names, conversation names and board names in Nextcloud Server 16.0.3, Nextcloud Talk 6.0.3 and Nextcloud Deck 0.6.5 causes an XSS when linking them with each others in a project.

    Product
    Deck
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 15, 2020JetBrains IDETalk plugin before version 193.4099.10 allows XXECVE-2019-18412 · Other software · Jetbrains · reported by MITREHigh 7.5

    JetBrains IDETalk plugin before version 193.4099.10 allows XXE

    Product
    Idetalk
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019The processCommandUploadLog() function of libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary CVE-2019-17364 · Other software · Skymee · reported by MITRECritical 9.8

    The processCommandUploadLog() function of libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands as the root user.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019The processCommandSetMac() function of libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary sysCVE-2019-16737 · Other software · Skymee · reported by MITRECritical 9.8

    The processCommandSetMac() function of libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands as the root user.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019A stack-based buffer overflow in processCommandUploadSnapshot in libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackerCVE-2019-16736 · Other software · Skymee · reported by MITRECritical 9.8

    A stack-based buffer overflow in processCommandUploadSnapshot in libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to cause denial of service or run arbitrary code as the root user.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019A stack-based buffer overflow in processCommandUploadLog in libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to CVE-2019-16735 · Other software · Skymee · reported by MITRECritical 9.8

    A stack-based buffer overflow in processCommandUploadLog in libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to cause denial of service or run arbitrary code as the root user.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019Use of default credentials for the TELNET server in Petwant PF-103 firmware 4.3.2.50 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system CVE-2019-16734 · Other software · Skymee · reported by MITRECritical 9.8

    Use of default credentials for the TELNET server in Petwant PF-103 firmware 4.3.2.50 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands as the root user.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019processCommandSetUid() in libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands CVE-2019-16733 · Other software · Skymee · reported by MITRECritical 9.8

    processCommandSetUid() in libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands as the root user.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019Unencrypted HTTP communications for firmware upgrades in Petalk AI and PF-103 allow man-in-the-middle attackers to run arbitrary code as the root user.CVE-2019-16732 · Other software · Skymee · reported by MITREHigh 8.1

    Unencrypted HTTP communications for firmware upgrades in Petalk AI and PF-103 allow man-in-the-middle attackers to run arbitrary code as the root user.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019The udpServerSys service in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to initiate firmware upgrades and alter device settCVE-2019-16731 · Other software · Skymee · reported by MITREHigh 7.5

    The udpServerSys service in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to initiate firmware upgrades and alter device settings.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2019processCommandUpgrade() in libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commandsCVE-2019-16730 · Other software · Skymee · reported by MITRECritical 9.8

    processCommandUpgrade() in libcommon.so in Petwant PF-103 firmware 4.22.2.42 and Petalk AI 3.2.2.30 allows remote attackers to execute arbitrary system commands as the root user.

    Product
    Petalk AI Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 22, 2019In the AppleTalk subsystem in the Linux kernel before 5.1, there is a potential NULL pointer dereference because register_snap_client may return NULL.CVE-2019-19227 · Computers, phones & browsers · Linux · reported by MITREMedium 5.5

    In the AppleTalk subsystem in the Linux kernel before 5.1, there is a potential NULL pointer dereference because register_snap_client may return NULL. This will lead to denial of service in net/appletalk/aarp.c and net/appletalk/ddp.c, as demonstrated by unregister_snap_client, aka CID-9804501fa122.

    Product
    Linux Kernel
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Nov 13, 2019The CleanTalk cleantalk-spam-protect plugin before 5.127.4 for WordPress is affected by: Cross Site Scripting (XSS).CVE-2019-17515 · WordPress plugins & themes · reported by MITREMedium 6.1

    The CleanTalk cleantalk-spam-protect plugin before 5.127.4 for WordPress is affected by: Cross Site Scripting (XSS). The impact is: Allows an attacker to execute arbitrary HTML and JavaScript code via the from or till parameter. The component is: inc/cleantalk-users.php and inc/cleantalk-comments.php. The attack vector is: When the Administrator is logged in, a reflected XSS may execute upon a click on a malicious URL.

    Product
    CleanTalk cleantalk-spam-protect
    Fixed in
    5.127.4
    What to do
    Update CleanTalk cleantalk-spam-protect to 5.127.4 or newer.
  • Oct 1, 2019atalk_create in net/appletalk/ddp.c in the AF_APPLETALK network module in the Linux kernel through 5.3.2 does not enforce CAP_NET_RAW, which means that unprivilCVE-2019-17054 · Computers, phones & browsers · Linux · reported by MITRELow 3.3

    atalk_create in net/appletalk/ddp.c in the AF_APPLETALK network module in the Linux kernel through 5.3.2 does not enforce CAP_NET_RAW, which means that unprivileged users can create a raw socket, aka CID-6cc03e8aa36c.

    Product
    Linux Kernel
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 18, 2019TechyTalk Quick Chat WordPress Plugin All up to the latest is affected by: SQL Injection.CVE-2019-1010104 · WordPress plugins & themes · reported by josh@bress.netCritical 9.8

    TechyTalk Quick Chat WordPress Plugin All up to the latest is affected by: SQL Injection. The impact is: Access to the database. The component is: like_escape is used in Quick-chat.php line 399. The attack vector is: Crafted ajax request.

    Affected
    up to 4.14
    What to do
    Affects up to 4.14. Update the plugin to the newest version and check its changelog mentions this fix; if there isn’t one yet, deactivate it until there is.
  • May 29, 2019ZxChat (aka ZeXtras Chat), as used for zimbra-chat and zimbra-talk in Synacor Zimbra Collaboration Suite 8.7 and 8.8 and in other products, allows XXE attacks, CVE-2018-20160 · Email & office · Synacor · reported by MITRECritical 9.8

    ZxChat (aka ZeXtras Chat), as used for zimbra-chat and zimbra-talk in Synacor Zimbra Collaboration Suite 8.7 and 8.8 and in other products, allows XXE attacks, as demonstrated by a crafted XML request to mailboxd.

    Product
    Zimbra Collaboration Suite
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 29, 2019esoTalk 1.0.0g4 has XSS via the PATH_INFO to the conversations/ URI.CVE-2015-9285 · Other software · Esotalk · reported by MITREMedium 6.1

    esoTalk 1.0.0g4 has XSS via the PATH_INFO to the conversations/ URI.

    Product
    Esotalk
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 25, 2019DaviewIndy 8.98.7 and earlier versions have a Integer overflow vulnerability, triggered when the user opens a malformed PDF file that is mishandled by Daview.exCVE-2019-9139 · Other software · HumanTalk Co,Ltd · reported by vuln@krcert.or.krHigh 7.8

    DaviewIndy 8.98.7 and earlier versions have a Integer overflow vulnerability, triggered when the user opens a malformed PDF file that is mishandled by Daview.exe. Attackers could exploit this and arbitrary code execution.

    Product
    DaviewIndy
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 25, 2019DaviewIndy 8.98.7 and earlier versions have a Integer overflow vulnerability, triggered when the user opens a malformed PhotoShop file that is mishandled by DavCVE-2019-9138 · Other software · HumanTalk Co,Ltd · reported by vuln@krcert.or.krHigh 7.8

    DaviewIndy 8.98.7 and earlier versions have a Integer overflow vulnerability, triggered when the user opens a malformed PhotoShop file that is mishandled by Daview.exe. Attackers could exploit this and arbitrary code execution.

    Product
    DaviewIndy
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 25, 2019DaviewIndy 8.98.7 and earlier versions have a Integer overflow vulnerability, triggered when the user opens a malformed Image file that is mishandled by Daview.CVE-2019-9137 · Other software · HumanTalk Co,Ltd · reported by vuln@krcert.or.krHigh 7.8

    DaviewIndy 8.98.7 and earlier versions have a Integer overflow vulnerability, triggered when the user opens a malformed Image file that is mishandled by Daview.exe. Attackers could exploit this and arbitrary code execution.

    Product
    DaviewIndy
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 25, 2019DaviewIndy 8.98.7 and earlier versions have a Heap-based overflow vulnerability, triggered when the user opens a malformed JPEG2000 format file that is mishandlCVE-2019-9136 · Other software · HumanTalk Co,Ltd · reported by vuln@krcert.or.krHigh 7.8

    DaviewIndy 8.98.7 and earlier versions have a Heap-based overflow vulnerability, triggered when the user opens a malformed JPEG2000 format file that is mishandled by Daview.exe. Attackers could exploit this and arbitrary code execution.

    Product
    DaviewIndy
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 25, 2019DaviewIndy 8.98.7 and earlier versions have a Heap-based overflow vulnerability, triggered when the user opens a malformed DIB format file that is mishandled byCVE-2019-9135 · Other software · HumanTalk Co,Ltd · reported by vuln@krcert.or.krHigh 7.8

    DaviewIndy 8.98.7 and earlier versions have a Heap-based overflow vulnerability, triggered when the user opens a malformed DIB format file that is mishandled by Daview.exe. Attackers could exploit this and arbitrary code execution.

    Product
    DaviewIndy
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 22, 2019In all versions of Unity8 a running but not active application on a large-screen device could talk with Maliit and consume keyboard input.CVE-2016-1584 · Other software · Ubuntu · reported by security@ubuntu.comLow 1.6

    In all versions of Unity8 a running but not active application on a large-screen device could talk with Maliit and consume keyboard input.

    Product
    Unity8
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 4, 2019Jenkins AWS Elastic Beanstalk Publisher Plugin stores credentials unencrypted in its global configuration file on the Jenkins master where they can be viewed byCVE-2019-1003052 · Websites & servers · Jenkins project · reported by jenkinsci-cert@googlegroups.comHigh 8.8

    Jenkins AWS Elastic Beanstalk Publisher Plugin stores credentials unencrypted in its global configuration file on the Jenkins master where they can be viewed by users with access to the master file system.

    Product
    Jenkins AWS Elastic Beanstalk Publisher Plugin
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 1, 2019Remote code execution vulnerability exists in KaKaoTalk PC messenger when user clicks specially crafted link in the message window.CVE-2019-9132 · Other software · KaKao · reported by vuln@krcert.or.krHigh 8.8

    Remote code execution vulnerability exists in KaKaoTalk PC messenger when user clicks specially crafted link in the message window. This affects KaKaoTalk windows version 2.7.5.2024 or lower.

    Product
    Kakaotalk Windows PC Messenger
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 24, 2019In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports reCVE-2018-18981 · Other software · Rockwell · reported by ics-cert@hq.dhs.govHigh 7.5

    In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial or complete denial-of-service condition to the affected services.

    Product
    Rockwell Automation FactoryTalk Services Platform v2.90 and earlier
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 20, 2018Netatalk before 3.1.12 is vulnerable to an out of bounds write in dsi_opensess.c.CVE-2018-1160 · Other software · Netatalk · reported by vulnreport@tenable.comCritical 9.8

    Netatalk before 3.1.12 is vulnerable to an out of bounds write in dsi_opensess.c. This is due to lack of bounds checking on attacker controlled data. A remote unauthenticated attacker can leverage this vulnerability to achieve arbitrary code execution.

    Product
    Netatalk
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Aug 13, 2018A missing sanitization of search results for an autocomplete field in NextCloud Talk <3.2.5 could lead to a stored XSS requiring user-interaction.CVE-2018-3781 · Other software · NextCloud · reported by support@hackerone.comMedium 5.4

    A missing sanitization of search results for an autocomplete field in NextCloud Talk <3.2.5 could lead to a stored XSS requiring user-interaction. The missing sanitization only affected user names, hence malicious search results could only be crafted by authenticated users.

    Product
    nextcloud/talk
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 7, 2018An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized,CVE-2018-10619 · Other software · ICS-CERT · reported by ics-cert@hq.dhs.govHigh 7.8

    An unquoted search path or element in RSLinx Classic Versions 3.90.01 and prior and FactoryTalk Linx Gateway Versions 3.90.00 and prior may allow an authorized, but non-privileged local user to execute arbitrary code and allow a threat actor to escalate user privileges on the affected workstation.

    Product
    Rockwell Automation RSLinx Classic and FactoryTalk Linx Gateway
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 6, 2018xtalk helps your browser talk to nodex, a simple web framework.CVE-2017-16091 · Other software · HackerOne · reported by support@hackerone.comHigh 7.5

    xtalk helps your browser talk to nodex, a simple web framework. xtalk is vulnerable to a directory traversal issue, giving an attacker access to the filesystem by placing "../" in the URL.

    Product
    xtalk node module
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 11, 2018Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an atCVE-2017-6015 · Other software · Rockwell Automation · reported by ics-cert@hq.dhs.govHigh 7.8

    Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

    Product
    FactoryTalk Activation
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 8, 2018The "XML Interface to Messaging, Scheduling, and Signaling" (XIMSS) protocol implementation in CommuniGate Pro (CGP) 6.2 suffers from a Missing XIMSS Protocol VCVE-2018-3815 · Other software · Stalker · reported by MITREMedium 5.7

    The "XML Interface to Messaging, Scheduling, and Signaling" (XIMSS) protocol implementation in CommuniGate Pro (CGP) 6.2 suffers from a Missing XIMSS Protocol Validation attack that leads to an email spoofing attack, allowing a malicious authenticated attacker to send a message from any source email address. The attack uses an HTTP POST request to a /Session URI, and interchanges the XML From and To elements.

    Product
    Communigate Pro
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 22, 2017An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier.CVE-2017-14022 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.5

    An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate.

    Product
    Factorytalk Alarms And Events
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 26, 2017Multiple SQL injection vulnerabilities in the Tapatalk plugin 4.9.0 and earlier and 5.x through 5.2.1 for vBulletin allow remote attackers to execute arbitrary CVE-2014-2023 · Other software · Tapatalk · reported by MITRECritical 9.8

    Multiple SQL injection vulnerabilities in the Tapatalk plugin 4.9.0 and earlier and 5.x through 5.2.1 for vBulletin allow remote attackers to execute arbitrary SQL commands via a crafted xmlrpc API request to (1) unsubscribe_forum.php or (2) unsubscribe_topic.php in mobiquo/functions/.

    Product
    Tapatalk
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Sep 21, 2017SQL Injection vulnerability in mobiquo/lib/classTTForum.php in the Tapatalk plugin before 4.5.8 for MyBB allows an unauthenticated remote attacker to inject arbCVE-2017-14652 · Other software · Tapatalk · reported by MITRECritical 9.8

    SQL Injection vulnerability in mobiquo/lib/classTTForum.php in the Tapatalk plugin before 4.5.8 for MyBB allows an unauthenticated remote attacker to inject arbitrary SQL commands via an XML-RPC encoded document sent as part of the user registration process.

    Product
    Tapatalk
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 23, 2017The (1) Special:MyPage, (2) Special:MyTalk, (3) Special:MyContributions, (4) Special:MyUploads, and (5) Special:AllMyUploads pages in MediaWiki before 1.23.12, CVE-2015-8628 · Other software · Mediawiki · reported by MITREMedium 5.3

    The (1) Special:MyPage, (2) Special:MyTalk, (3) Special:MyContributions, (4) Special:MyUploads, and (5) Special:AllMyUploads pages in MediaWiki before 1.23.12, 1.24.x before 1.24.5, 1.25.x before 1.25.4, and 1.26.x before 1.26.1 allow remote attackers to obtain sensitive user login information via crafted links combined with page view statistics.

    Product
    Mediawiki
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2017The AppleTalk parser in tcpdump before 4.9.0 has a buffer overflow in print-atalk.c, multiple functions.CVE-2016-7973 · Other software · Tcpdump · reported by MITRECritical 9.8

    The AppleTalk parser in tcpdump before 4.9.0 has a buffer overflow in print-atalk.c, multiple functions.

    Product
    Tcpdump
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 27, 2016Rockwell Automation FactoryTalk EnergyMetrix before 2.20.00 does not invalidate credentials upon a logout action, which makes it easier for remote attackers to CVE-2016-4531 · Other software · Rockwellautomation · reported by ics-cert@hq.dhs.govHigh 7.3

    Rockwell Automation FactoryTalk EnergyMetrix before 2.20.00 does not invalidate credentials upon a logout action, which makes it easier for remote attackers to obtain access by leveraging an unattended workstation.

    Product
    Factorytalk Energrymetrix
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.