Jan 31, 2020Integer overflow in the Drive Execution Environment (DXE) phase in the Capsule Update feature in the UEFI implementation in EDK2 allows physically proximate attCVE-2014-4859 · Other software · Phoenix Technologies Ltd. · reported by cret@cert.orgMedium 6.8
Integer overflow in the Drive Execution Environment (DXE) phase in the Capsule Update feature in the UEFI implementation in EDK2 allows physically proximate attackers to bypass intended access restrictions via crafted data.
- Product
- SCT3
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordkb.cert.orgkb.cert.org
Nov 13, 2019In Phoenix SCT WinFlash 1.1.12.0 through 1.5.74.0, the included drivers could be used by a malicious Windows application to gain elevated privileges.CVE-2019-18279 · Other software · Phoenix · reported by MITREHigh 8.8
In Phoenix SCT WinFlash 1.1.12.0 through 1.5.74.0, the included drivers could be used by a malicious Windows application to gain elevated privileges. Adverse impacts are limited to the Windows environment and there is no known direct impact to the UEFI firmware. This was fixed in late June 2019.
- Product
- Securecore Technology
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordeclypsium.comeclypsium.com
Oct 31, 2019An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86.CVE-2019-16675 · Other software · Phoenixcontact · reported by MITREHigh 7.8
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-of-bounds Read and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project to be able to manipulate data inside. After manipulation, the attacker needs to exchange the original files with the manipulated ones on the application programming workstation.
- Product
- Config+
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert.vde.comus-cert.gov
Jun 24, 2019An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86.CVE-2019-12870 · Other software · Phoenixcontact · reported by MITREHigh 8.8
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Uninitialized Pointer and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation.
- Product
- Automationworx Software Suite
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert.vde.comzerodayinitiative.com
Jun 24, 2019An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86.CVE-2019-12869 · Other software · Phoenixcontact · reported by MITREHigh 8.8
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to an Out-Of-Bounds Read, Information Disclosure, and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation.
- Product
- Automationworx Software Suite
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert.vde.comzerodayinitiative.com
Jun 24, 2019An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86.CVE-2019-12871 · Other software · Phoenixcontact · reported by MITREHigh 8.8
An issue was discovered in PHOENIX CONTACT PC Worx through 1.86, PC Worx Express through 1.86, and Config+ through 1.86. A manipulated PC Worx or Config+ project file could lead to a Use-After-Free and remote code execution. The attacker needs to get access to an original PC Worx or Config+ project file to be able to manipulate it. After manipulation, the attacker needs to exchange the original file with the manipulated one on the application programming workstation.
- Product
- Automationworx Software Suite
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert.vde.comzerodayinitiative.com
Jun 18, 2019An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices.CVE-2019-10998 · Other software · Phoenixcontact · reported by MITREMedium 6.8
An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Unlimited physical access to the PLC may lead to a manipulation of SD cards data. SD card manipulation may lead to an authentication bypass opportunity.
- Product
- AXC F 2152 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddam-mdc.phoenixcontact.comdam-mdc.phoenixcontact.com
Jun 17, 2019An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices.CVE-2019-10997 · Other software · Phoenixcontact · reported by MITREMedium 5.9
An issue was discovered on Phoenix Contact AXC F 2152 (No.2404267) before 2019.0 LTS and AXC F 2152 STARTERKIT (No.1046568) before 2019.0 LTS devices. Protocol Fuzzing on PC WORX Engineer by a man in the middle attacker stops the PLC service. The device must be rebooted, or the PLC service must be restarted manually via a Linux shell.
- Product
- AXC F 2152 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddam-mdc.phoenixcontact.comdam-mdc.phoenixcontact.com
May 7, 2019The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 is vulnerable to a denial-of-service attack by making more than 120 connections.CVE-2018-13994 · Other software · Phoenixcontact · reported by MITREHigh 7.5
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 is vulnerable to a denial-of-service attack by making more than 120 connections.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
May 7, 2019The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 is prone to CSRF.CVE-2018-13993 · Other software · Phoenixcontact · reported by MITREHigh 8.8
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 is prone to CSRF.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
May 7, 2019The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 allows for plaintext transmission (HTTP) of user credentials by default.CVE-2018-13992 · Other software · Phoenixcontact · reported by MITREHigh 8.2
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 allows for plaintext transmission (HTTP) of user credentials by default.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
May 7, 2019The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 leaks private information in firmware images.CVE-2018-13991 · Other software · Phoenixcontact · reported by MITREMedium 5.3
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions 1.0 to 1.34 leaks private information in firmware images.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
May 6, 2019The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions prior to 1.35 is vulnerable to brute-force attacks, because of Improper Restriction of ExcessivCVE-2018-13990 · Other software · Phoenixcontact · reported by MITREHigh 8.6
The WebUI of PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, 48xx versions prior to 1.35 is vulnerable to brute-force attacks, because of Improper Restriction of Excessive Authentication Attempts.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Apr 17, 2019ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions.CVE-2019-10953 · Other software · ABB · reported by ics-cert@hq.dhs.govHigh 7.5
ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets.
- Product
- 1SAP120600R0071 PM554-TP-ETH
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comgithub.com
Mar 26, 2019An issue was discovered on PHOENIX CONTACT FL NAT SMCS 8TX, FL NAT SMN 8TX, FL NAT SMN 8TX-M, and FL NAT SMN 8TX-M-DMG devices.CVE-2019-9744 · Other software · Phoenixcontact · reported by MITREHigh 8.8
An issue was discovered on PHOENIX CONTACT FL NAT SMCS 8TX, FL NAT SMN 8TX, FL NAT SMN 8TX-M, and FL NAT SMN 8TX-M-DMG devices. There is unauthorized access to the WEB-UI by attackers arriving from the same source IP address as an authenticated user, because this IP address is used as a session identifier.
- Product
- FL NAT SMN 8tx-m-dmg Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcert.vde.com
Mar 26, 2019An issue was discovered on PHOENIX CONTACT RAD-80211-XD and RAD-80211-XD/HP-BUS devices.CVE-2019-9743 · Other software · Phoenixcontact · reported by MITREHigh 8.8
An issue was discovered on PHOENIX CONTACT RAD-80211-XD and RAD-80211-XD/HP-BUS devices. Command injection can occur in the WebHMI component.
- Product
- Rad-80211-xd/hp-bus Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcert.vde.com
Feb 26, 2019Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstratedCVE-2019-9201 · Other software · Phoenixcontact · reported by MITRECritical 9.8
Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories.
- Product
- ILC 131 ETH Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert.vde.commedium.com
May 17, 2018All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 are prone to buffer overflows when handling very large cookCVE-2018-10731 · Other software · Phoenixcontact · reported by MITRECritical 9
All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 are prone to buffer overflows when handling very large cookies (a different vulnerability than CVE-2018-10728).
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcert.vde.com
May 17, 2018All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 are prone to OS command injection.CVE-2018-10730 · Other software · Phoenixcontact · reported by MITRECritical 9.1
All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 are prone to OS command injection.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcert.vde.com
May 17, 2018All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 allow reading the configuration file by an unauthenticated CVE-2018-10729 · Other software · Phoenixcontact · reported by MITREMedium 5.3
All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 allow reading the configuration file by an unauthenticated user.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcert.vde.com
May 17, 2018All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 are prone to buffer overflows (a different vulnerability thCVE-2018-10728 · Other software · Phoenixcontact · reported by MITREHigh 8.1
All Phoenix Contact managed FL SWITCH 3xxx, 4xxx, 48xx products running firmware version 1.0 to 1.33 are prone to buffer overflows (a different vulnerability than CVE-2018-10731).
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcert.vde.com
Apr 5, 2018The web server in Phoenix Contact ILC PLCs allows access to read and write PLC variables without authentication.CVE-2016-8380 · Other software · Phoenix Contact · reported by ics-cert@hq.dhs.govHigh 7.3
The web server in Phoenix Contact ILC PLCs allows access to read and write PLC variables without authentication.
- Product
- Phoenix Contact ILC PLCs
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Apr 5, 2018The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled.CVE-2016-8371 · Other software · Phoenix Contact · reported by ics-cert@hq.dhs.govHigh 7.3
The web server in Phoenix Contact ILC PLCs can be accessed without authenticating even if the authentication mechanism is enabled.
- Product
- Phoenix Contact ILC PLCs
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Apr 5, 2018Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user.CVE-2016-8366 · Other software · Phoenix Contact · reported by ics-cert@hq.dhs.govHigh 7.3
Webvisit in Phoenix Contact ILC PLCs offers a password macro to protect HMI pages on the PLC against casual or coincidental opening of HMI pages by the user. The password macro can be configured in a way that the password is stored and transferred in clear text.
- Product
- Phoenix Contact ILC PLCs
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Jan 30, 2018An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0.CVE-2018-5441 · Other software · Phoenixcontact · reported by ics-cert@hq.dhs.govHigh 7.8
An Improper Validation of Integrity Check Value issue was discovered in PHOENIX CONTACT mGuard firmware versions 7.2 to 8.6.0. mGuard devices rely on internal checksums for verification of the internal integrity of the update packages. Verification may not always be performed correctly, allowing an attacker to modify firmware update packages.
- Product
- Mguard Centerport Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcert.vde.com
Jan 13, 2018Icy Phoenix 2.2.0.105 allows SQL injection via an unapprove request to admin_kb_art.php or the order parameter to admin_jr_admin.php, related to functions_kb.phCVE-2018-5697 · Other software · Icyphoenix · reported by MITREHigh 7.2
Icy Phoenix 2.2.0.105 allows SQL injection via an unapprove request to admin_kb_art.php or the order parameter to admin_jr_admin.php, related to functions_kb.php.
- Product
- Icyphoenix
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordvulnerability-lab.comvulnerability-lab.com
Jan 12, 2018An Improper Authorization issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0 to 1.32.CVE-2017-16743 · Other software · Phoenixcontact · reported by ics-cert@hq.dhs.govCritical 9.8
An Improper Authorization issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0 to 1.32. A remote unauthenticated attacker may be able to craft special HTTP requests allowing an attacker to bypass web-service authentication allowing the attacker to obtain administrative privileges on the device.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert.vde.comics-cert.us-cert.gov
Jan 12, 2018An Information Exposure issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0 to 1.32.CVE-2017-16741 · Other software · Phoenixcontact · reported by ics-cert@hq.dhs.govMedium 5.3
An Information Exposure issue was discovered in PHOENIX CONTACT FL SWITCH 3xxx, 4xxx, and 48xxx Series products running firmware Version 1.0 to 1.32. A remote unauthenticated attacker may be able to use Monitor Mode on the device to read diagnostic information.
- Product
- FL Switch 3005 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcert.vde.comics-cert.us-cert.gov
Dec 11, 2017A Cross-site Scripting issue was discovered in PHOENIX CONTACT FL COMSERVER BASIC 232/422/485, FL COMSERVER UNI 232/422/485, FL COMSERVER BAS 232/422/485-T, FL CVE-2017-16723 · Other software · Phoenixcontact · reported by ics-cert@hq.dhs.govMedium 6.1
A Cross-site Scripting issue was discovered in PHOENIX CONTACT FL COMSERVER BASIC 232/422/485, FL COMSERVER UNI 232/422/485, FL COMSERVER BAS 232/422/485-T, FL COMSERVER UNI 232/422/485-T, FL COM SERVER RS232, FL COM SERVER RS485, and PSI-MODEM/ETH (running firmware versions prior to 1.99, 2.20, or 2.40). The cross-site scripting vulnerability has been identified, which may allow remote code execution.
- Product
- FL Comserver Basic 232 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comcert.vde.com
Nov 17, 2017The Phoenix Framework versions 1.0.0 through 1.0.4, 1.1.0 through 1.1.6, 1.2.0, 1.2.2 and 1.3.0-rc.0 are vulnerable to unvalidated URL redirection, which may reCVE-2017-1000163 · Other software · Phoenixframework · reported by MITREMedium 6.1
The Phoenix Framework versions 1.0.0 through 1.0.4, 1.1.0 through 1.1.6, 1.2.0, 1.2.2 and 1.3.0-rc.0 are vulnerable to unvalidated URL redirection, which may result in phishing or social engineering attacks.
- Product
- Phoenix
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordelixirforum.comelixirforum.com
Jul 25, 2017Intense PC Phoenix SecureCore UEFI firmware does not perform capsule signature validation before upgrading the system firmware.CVE-2017-9457 · Other software · Compulab · reported by MITREMedium 6.7
Intense PC Phoenix SecureCore UEFI firmware does not perform capsule signature validation before upgrading the system firmware. The absence of signature validation allows an attacker with administrator privileges to flash a modified UEFI BIOS.
- Product
- Intense PC Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.comseclists.org
Jun 2, 2017A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87.CVE-2017-6039 · Other software · Phoenixbroadband · reported by ics-cert@hq.dhs.govMedium 5.3
A Use of Hard-Coded Password issue was discovered in Phoenix Broadband PowerAgent SC3 BMS, all versions prior to v6.87. Use of a hard-coded password may allow unauthorized access to the device.
- Product
- Poweragent Sc3 BMS Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
May 18, 2017An Improper Authentication issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2.CVE-2017-7937 · Other software · Phoenix Contact Gmbh · reported by ics-cert@hq.dhs.govMedium 4
An Improper Authentication issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may be able to gain unauthorized access to the user firewall when RADIUS servers are unreachable.
- Product
- Mguard Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
May 18, 2017A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2.CVE-2017-7935 · Other software · Phoenix Contact Gmbh · reported by ics-cert@hq.dhs.govHigh 7.5
A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may compromise the device's availability by performing multiple initial VPN requests.
- Product
- Mguard Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Feb 13, 2017An issue was discovered on Phoenix Contact mGuard devices that have been updated to Version 8.4.0.CVE-2017-5159 · Other software · Phoenixcontact · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered on Phoenix Contact mGuard devices that have been updated to Version 8.4.0. When updating an mGuard device to Version 8.4.0 via the update-upload facility, the update will succeed, but it will reset the password of the admin user to its default value.
- Product
- Mguard Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Jan 16, 2015Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant trafficCVE-2014-9195 · Other software · Phoenix Contact · reported by ics-cert@hq.dhs.govHigh 10
Phoenix Contact ProConOs and MultiProg do not require authentication, which allows remote attackers to execute arbitrary commands via protocol-compliant traffic.
- Product
- ProConOs
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcisa.govexploit-db.com
Sep 6, 2012Multiple untrusted search path vulnerabilities in Phoenix Project Manager 2.1.0.8 allow local users to gain privileges via a Trojan horse (1) wbtrv32.dll or (2)CVE-2010-5223 · Other software · Phoenixcpm · reported by MITREMedium 6.9
Multiple untrusted search path vulnerabilities in Phoenix Project Manager 2.1.0.8 allow local users to gain privileges via a Trojan horse (1) wbtrv32.dll or (2) w3btrv7.dll file in the current working directory, as demonstrated by a directory that contains a .ppx file. NOTE: some of these details are obtained from third party information.
- Product
- Phoenix Project Manager
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordpacketstormsecurity.orgsecunia.com
Sep 10, 2009Phoenix Contact FL IL 24 BK-PAC allows remote attackers to cause a denial of service (hang) via (1) unspecified manipulations as demonstrated by a Nessus scan oCVE-2008-7199 · Other software · Phoenixcontact · reported by MITREMedium 5
Phoenix Contact FL IL 24 BK-PAC allows remote attackers to cause a denial of service (hang) via (1) unspecified manipulations as demonstrated by a Nessus scan or (2) malformed input to TCP port 502.
- Product
- FL IL 24 Bk-pac
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordarchives.neohapsis.comosvdb.org
Jun 3, 2008Directory traversal vulnerability in admin/admin_frame.php in Phoenix View CMS Pre Alpha2 and earlier allows remote attackers to include and execute arbitrary lCVE-2008-2534 · Other software · Fkrauthan · reported by MITREHigh 7.5
Directory traversal vulnerability in admin/admin_frame.php in Phoenix View CMS Pre Alpha2 and earlier allows remote attackers to include and execute arbitrary local files via a .. (dot dot) in the ltarget parameter.
- Product
- Phoenix View CMS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordexchange.xforce.ibmcloud.comexploit-db.com
Jun 3, 2008Multiple SQL injection vulnerabilities in Phoenix View CMS Pre Alpha2 and earlier allow remote attackers to execute arbitrary SQL commands via the del parameterCVE-2008-2535 · Other software · Fkrauthan · reported by MITREHigh 7.5
Multiple SQL injection vulnerabilities in Phoenix View CMS Pre Alpha2 and earlier allow remote attackers to execute arbitrary SQL commands via the del parameter to (1) gbuch.admin.php, (2) links.admin.php, (3) menue.admin.php, (4) news.admin.php, and (5) todo.admin.php in admin/module/.
- Product
- Phoenix View CMS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordexchange.xforce.ibmcloud.comexploit-db.com
Jun 3, 2008Multiple cross-site scripting (XSS) vulnerabilities in Phoenix View CMS Pre Alpha2 and earlier allow remote attackers to inject arbitrary web script or HTML viaCVE-2008-2533 · Other software · Fkrauthan · reported by MITREMedium 4.3
Multiple cross-site scripting (XSS) vulnerabilities in Phoenix View CMS Pre Alpha2 and earlier allow remote attackers to inject arbitrary web script or HTML via the (1) ltarget parameter to (a) admin/admin_frame.php and the (2) conf parameter to (b) gbuch.admin.php, (c) links.admin.php, (d) menue.admin.php, (e) news.admin.php, and (f) todo.admin.php in admin/module/.
- Product
- Phoenix View CMS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comexchange.xforce.ibmcloud.com
Jan 23, 2008Directory traversal vulnerability in administrator/download.php in IDMOS (aka Phoenix) 1.0 allows remote attackers to read arbitrary files via a ..CVE-2008-0431 · Other software · Idmos · reported by MITREMedium 5
Directory traversal vulnerability in administrator/download.php in IDMOS (aka Phoenix) 1.0 allows remote attackers to read arbitrary files via a .. (dot dot) in the fileName parameter.
- Product
- Idmos CMS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecunia.comsecurityfocus.com
Nov 7, 2007Multiple PHP remote file inclusion vulnerabilities in IDMOS 1.0 Alpha (aka Phoenix) allow remote attackers to execute arbitrary PHP code via a URL in the site_aCVE-2007-5889 · Other software · Idmos · reported by MITREHigh 10
Multiple PHP remote file inclusion vulnerabilities in IDMOS 1.0 Alpha (aka Phoenix) allow remote attackers to execute arbitrary PHP code via a URL in the site_absolute_path parameter to (1) admin.php, (2) menu_add.php, and (3) menu_operation.php in administrator/, different vectors than CVE-2007-5294.
- Product
- Idmos
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 9, 2007PHP remote file inclusion vulnerability in core/aural.php in IDMOS 1.0-beta (aka Phoenix) allows remote attackers to execute arbitrary PHP code via a URL in theCVE-2007-5294 · Other software · Idmos · reported by MITREMedium 6.8
PHP remote file inclusion vulnerability in core/aural.php in IDMOS 1.0-beta (aka Phoenix) allows remote attackers to execute arbitrary PHP code via a URL in the site_absolute_path parameter.
- Product
- Idmos
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordosvdb.orgsecurityreason.com
Oct 9, 2007Multiple cross-site scripting (XSS) vulnerabilities in IDMOS 1.0-beta (aka Phoenix) allow remote attackers to inject arbitrary web script or HTML via the (1) erCVE-2007-5293 · Other software · Idmos · reported by MITRELow 2.6
Multiple cross-site scripting (XSS) vulnerabilities in IDMOS 1.0-beta (aka Phoenix) allow remote attackers to inject arbitrary web script or HTML via the (1) err_msg parameter to error.php and the (2) content parameter to templates/simple/ia.php.
- Product
- Idmos
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Sep 29, 2006Multiple cross-site scripting (XSS) vulnerabilities in Phoenix Evolution CMS (PECMS) allow remote attackers to inject arbitrary web script or HTML via the (1) mCVE-2006-5090 · Other software · Phoenix Evolution · reported by MITREMedium 6.8
Multiple cross-site scripting (XSS) vulnerabilities in Phoenix Evolution CMS (PECMS) allow remote attackers to inject arbitrary web script or HTML via the (1) mod or (2) action parameters in index.php, or the (3) pageid parameter in modules/pageedit/index.php. NOTE: the provenance of this information is unknown; the details are obtained from third party information.
- Product
- Phoenix Evolution CMS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 24, 2004The Phoenix browser in eSeSIX Thintune thin clients running firmware 2.4.38 and earlier allows local users to read arbitrary files via a file:/// URL.CVE-2004-2051 · Other software · Esesix · reported by MITREMedium 5
The Phoenix browser in eSeSIX Thintune thin clients running firmware 2.4.38 and earlier allows local users to read arbitrary files via a file:/// URL.
- Product
- Thintune Extreme
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.