Vulnerability database
Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.
445 results · page 5 of 9
Dec 13, 2022Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Command Injection via lform/net_diagnose.CVE-2022-42140 · Other software · Deltaww · reported by MITREHigh 7.2
Delta Electronics DX-2100-L1-CN 2.42 is vulnerable to Command Injection via lform/net_diagnose.
- Product
- Dx-2100-l1-cn Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcyberdanube.comcyberdanube.com
Dec 13, 2022Delta Electronics DVW-W02W2-E2 1.5.0.10 is vulnerable to Command Injection via Crafted URL.CVE-2022-42139 · Other software · Deltaww · reported by MITREHigh 8.8
Delta Electronics DVW-W02W2-E2 1.5.0.10 is vulnerable to Command Injection via Crafted URL.
- Product
- Dvw-w02w2-e2 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordcyberdanube.comcyberdanube.com
Dec 13, 2022Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrCVE-2022-2660 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Industrial Automation DIALink versions 1.4.0.0 and prior are vulnerable to the use of a hard-coded cryptographic key which could allow an attacker to decrypt sensitive data and compromise the machine.
- Product
- Industrial Automation DIALink
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Dec 1, 2022Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory loCVE-2022-2969 · Other software · Delta Industrial Automation · reported by ics-cert@hq.dhs.govHigh 8.1
Delta Industrial Automation DIALink versions prior to v1.5.0.0 Beta 4 uses an external input to construct a pathname intended to identify a file or directory located underneath a restricted parent directory. However, the software does not properly neutralize special elements within the pathname, which can cause the pathname to resolve to a location outside of the restricted directory.
- Product
- DIALink
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Nov 17, 2022SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via NetworkCVE-2022-43506 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
SQL Injection in HandlerTag_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Nov 17, 2022SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via NetCVE-2022-43457 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
SQL Injection in HandlerPage_KID.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Nov 17, 2022SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via NeCVE-2022-43452 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
SQL Injection in FtyInfoSetting.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Nov 17, 2022SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via NetwCVE-2022-43447 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
SQL Injection in AM_EBillAnalysis.aspx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Nov 17, 2022SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via NetworkCVE-2022-41775 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
SQL Injection in Handler_CFG.ashx in Delta Electronics DIAEnergie versions prior to v1.9.02.001 allows an attacker to inject SQL queries via Network
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification.CVE-2022-41779 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allowCVE-2022-41776 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.5
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal.CVE-2022-41772 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior mishandle .ZIP archives containing characters used in path traversal. This path traversal could result in remote code execution.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups.CVE-2022-41688 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operatioCVE-2022-41657 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior allow attacker provided data already serialized into memory to be used in file operation application programmable interfaces (APIs). This could create arbitrary files, which could be used in API operations and could ultimately result in remote code execution.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges.CVE-2022-41644 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lacks authentication for a function that changes group privileges. An attacker could use this to create a denial-of-service state or escalate their own privileges.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attaCVE-2022-41629 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.5
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to access the aprunning endpoint, which could allow an attacker to retrieve any file from the “RunningConfigs” directory. The attacker could then view and modify configuration files such as UserListInfo.xml, which would allow them to see existing administrative passwords.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication.CVE-2022-40202 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 31, 2022 Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port withoutCVE-2022-38142 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization.
- Product
- InfraSuite Device Master
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 27, 2022The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud.CVE-2022-41773 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckDIACloud. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 27, 2022The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API.CVE-2022-41702 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.7
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the InsertReg API.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 27, 2022The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API.CVE-2022-41701 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.7
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutShift API.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 27, 2022The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API.CVE-2022-41651 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.7
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the SetPF API.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 27, 2022The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting ACVE-2022-41555 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.7
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PutLineMessageSetting API.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 27, 2022The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters.CVE-2022-41133 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in GetDIAE_line_message_settingsListParameters. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 27, 2022The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted.CVE-2022-40967 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.8
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a SQL injection that exists in CheckIoTHubNameExisted. A low-privileged authenticated attacker could exploit this issue to inject arbitrary SQL queries.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 27, 2022The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API.CVE-2022-40965 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 8.7
The affected product DIAEnergie (versions prior to v1.9.01.002) is vulnerable to a stored cross-site scripting vulnerability through the PostEnergyType API.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Oct 26, 2022The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.CVE-2022-43775 · Other software · Deltaww · reported by vulnreport@tenable.comCritical 9.8
The HICT_Loop class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
- Product
- Diaenergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtenable.comtenable.com
Oct 26, 2022The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote sysCVE-2022-43774 · Other software · Deltaww · reported by vulnreport@tenable.comCritical 9.8
The HandlerPageP_KID class in Delta Electronics DIAEnergy v1.9 contains a SQL Injection flaw that could allow an attacker to gain code execution on a remote system.
- Product
- Diaenergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordtenable.comtenable.com
Sep 16, 2022Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials.CVE-2022-3214 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Industrial Automation's DIAEnergy, an industrial energy management system, is vulnerable to CWE-798, Use of Hard-coded Credentials. Versions prior to 1.9.03.009 have this vulnerability. Executable files could be uploaded to certain directories using hard-coded bearer authorization, allowing remote code execution.
- Product
- DIAEnergy
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Sep 13, 2022In NLnet Labs Routinator 0.9.0 up to and including 0.11.2, due to a mistake in error handling, data in RRDP snapshot and delta files that isn’t correctly base 6CVE-2022-3029 · Other software · NLnet Labs · reported by sep@nlnetlabs.nlHigh 7.5
In NLnet Labs Routinator 0.9.0 up to and including 0.11.2, due to a mistake in error handling, data in RRDP snapshot and delta files that isn’t correctly base 64 encoded is treated as a fatal error and causes Routinator to exit. Worst case impact of this vulnerability is denial of service for the RPKI data that Routinator provides to routers. This may stop your network from validating route origins based on RPKI data. This vulnerability does not allow an attacker to manipulate RPKI data.
- Product
- Routinator
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordnlnetlabs.nlnlnetlabs.nl
Aug 31, 2022Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML documCVE-2022-2759 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govMedium 5.5
Delta Electronics Delta Robot Automation Studio (DRAS) versions prior to 1.13.20 are affected by improper restrictions where the software processes an XML document that can contain XML entities with URIs that resolve to documents outside of the intended sphere of control, causing the product to embed incorrect documents into its output. This may allow an attacker to view sensitive documents and information on the affected host.
- Product
- Delta Robot Automation Studio (DRAS)
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 31, 2022CNCSoft: All versions prior to 1.01.32 does not properly sanitize input while processing a specific project file, allowing a possible stack-based buffer overfloCVE-2022-1405 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.8
CNCSoft: All versions prior to 1.01.32 does not properly sanitize input while processing a specific project file, allowing a possible stack-based buffer overflow condition.
- Product
- CNCSoft
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Aug 31, 2022Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-CVE-2022-1404 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govLow 3.3
Delta Electronics CNCSoft (All versions prior to 1.01.32) does not properly sanitize input while processing a specific project file, allowing a possible out-of-bounds read condition.
- Product
- CNCSoft
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 26, 2022The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords.CVE-2022-29965 · Other software · Emerson · reported by MITREMedium 5.5
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. Access to privileged operations on the maintenance port TELNET interface (23/TCP) on M-series and SIS (CSLS/LSNB/LSNG) nodes is controlled by means of utility passwords. These passwords are generated using a deterministic, insecure algorithm using a single seed value composed of a day/hour/minute timestamp with less than 16 bits of entropy. The seed value is fed through a lookup table and a series of permutation operations resulting in three different four-character passwords corresponding to different privilege levels. An attacker can easily reconstruct these passwords and thus gain access to privileged maintenance operations. NOTE: this is different from CVE-2014-2350.
- Product
- Deltav Distributed Control System
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 26, 2022The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords.CVE-2022-29964 · Other software · Emerson · reported by MITREMedium 5.5
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. WIOC SSH provides access to a shell as root, DeltaV, or backup via hardcoded credentials. NOTE: this is different from CVE-2014-2350.
- Product
- Deltav Distributed Control System SQ Controller Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 26, 2022The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords.CVE-2022-29963 · Other software · Emerson · reported by MITREMedium 5.5
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. TELNET on port 18550 provides access to a root shell via hardcoded credentials. This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350.
- Product
- Deltav Distributed Control System SQ Controller Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 26, 2022The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords.CVE-2022-29962 · Other software · Emerson · reported by MITREMedium 5.5
The Emerson DeltaV Distributed Control System (DCS) controllers and IO cards through 2022-04-29 misuse passwords. FTP has hardcoded credentials (but may often be disabled in production). This affects S-series, P-series, and CIOC/EIOC nodes. NOTE: this is different from CVE-2014-2350.
- Product
- Deltav Distributed Control System SQ Controller Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jul 26, 2022The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication.CVE-2022-29957 · Other software · Emerson · reported by MITREHigh 7.8
The Emerson DeltaV Distributed Control System (DCS) through 2022-04-29 mishandles authentication. It utilizes several proprietary protocols for a wide variety of functionality. These protocols include Firmware upgrade (18508/TCP, 18518/TCP); Plug-and-Play (18510/UDP); Hawk services (18507/UDP); Management (18519/TCP); Cold restart (18512/UDP); SIS communications (12345/TCP); and Wireless Gateway Protocol (18515/UDP). None of these protocols have any authentication features, allowing any attacker capable of communicating with the ports in question to invoke (a subset of) desired functionality.
- Product
- Deltav Distributed Control System
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jun 27, 2022A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1.08.00 allows attackers to execute arbitCVE-2022-33005 · Other software · Deltaww · reported by MITREMedium 6.1
A cross-site scripting (XSS) vulnerability in the System Settings/IOT Settings module of Delta Electronics DIAEnergie v1.08.00 allows attackers to execute arbitrary web scripts via a crafted payload injected into the Name text field.
- Product
- Diaenergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Jun 2, 2022Delta Controls enteliTOUCH 3.40.3935, 3.40.3706, and 3.33.4005 allows attackers to execute arbitrary commands via a crafted HTTP request.CVE-2022-29735 · Other software · Deltacontrols · reported by MITREHigh 8.8
Delta Controls enteliTOUCH 3.40.3935, 3.40.3706, and 3.33.4005 allows attackers to execute arbitrary commands via a crafted HTTP request.
- Product
- Entelitouch Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddeltacontrols.comzeroscience.mk
Jun 2, 2022Delta Controls enteliTOUCH 3.40.3935, 3.40.3706, and 3.33.4005 was discovered to transmit and store sensitive information in cleartext.CVE-2022-29733 · Other software · Deltacontrols · reported by MITREMedium 5.9
Delta Controls enteliTOUCH 3.40.3935, 3.40.3706, and 3.33.4005 was discovered to transmit and store sensitive information in cleartext. This vulnerability allows attackers to intercept HTTP Cookie authentication credentials via a man-in-the-middle attack.
- Product
- Entelitouch Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddeltacontrols.comzeroscience.mk
Jun 2, 2022Delta Controls enteliTOUCH 3.40.3935, 3.40.3706, and 3.33.4005 was discovered to contain a cross-site scripting (XSS) vulnerability via the Username parameter.CVE-2022-29732 · Other software · Deltacontrols · reported by MITREMedium 6.1
Delta Controls enteliTOUCH 3.40.3935, 3.40.3706, and 3.33.4005 was discovered to contain a cross-site scripting (XSS) vulnerability via the Username parameter. This vulnerability allows attackers to execute arbitrary web scripts or HTML via a crafted payload.
- Product
- Entelitouch Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddeltacontrols.comzeroscience.mk
May 24, 2022Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to an out-of-bounds write condition, which may result in a system crash or allow an attacker CVE-2021-32969 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.8
Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to an out-of-bounds write condition, which may result in a system crash or allow an attacker to remotely execute arbitrary code.
- Product
- DIAScreen
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 24, 2022Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to type confusion, which may allow an attacker to remotely execute arbitrary code.CVE-2021-32965 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govHigh 7.8
Delta Electronics DIAScreen versions prior to 1.1.0 are vulnerable to type confusion, which may allow an attacker to remotely execute arbitrary code.
- Product
- DIAScreen
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 3, 2022In four instances DMARS (All versions prior to v2.1.10.24) does not properly restrict references of XML external entities while processing specific project fileCVE-2022-1331 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govMedium 5.5
In four instances DMARS (All versions prior to v2.1.10.24) does not properly restrict references of XML external entities while processing specific project files, which may allow unauthorized information disclosure.
- Product
- DMARS
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 2, 2022Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx.CVE-2022-1378 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_pgHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 2, 2022Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_rltHandler.ashx.CVE-2022-1377 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_rltHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 2, 2022Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_privgrpHandler.ashx.CVE-2022-1376 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_privgrpHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 2, 2022Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_slogHandler.ashx.CVE-2022-1375 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_slogHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
May 2, 2022Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx.CVE-2022-1374 · Other software · Delta Electronics · reported by ics-cert@hq.dhs.govCritical 9.8
Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) has a blind SQL injection vulnerability exists in DIAE_unHandler.ashx. This allows an attacker to inject arbitrary SQL queries, retrieve and modify database contents, and execute system commands.
- Product
- DIAEnergie
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.