Jun 29, 2017A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXPCVE-2017-6017 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.5
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
- Product
- Bmxnoc0401 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Jun 7, 2017A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on thCVE-2017-7966 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 8.8
A DLL Hijacking vulnerability in the programming software in Schneider Electric's SoMachine HVAC v2.1.0 allows a remote attacker to execute arbitrary code on the targeted system. The vulnerability exists due to the improper loading of a DLL.
- Product
- SoMachine HVAC Programming Software
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordschneider-electric.comsecurityfocus.com
Jun 7, 2017A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 CVE-2017-7965 · Other software · Schneider Electric SE · reported by cybersecurity@se.comHigh 7.3
A buffer overflow vulnerability exists in Programming Software executable AlTracePrint.exe, in Schneider Electric's SoMachine HVAC v2.1.0 for Modicon M171/M172 Controller.
- Product
- SoMachine HVAC Programming Software
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordschneider-electric.comsecurityfocus.com
May 19, 2017An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions.CVE-2017-7968 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8
An Incorrect Default Permissions issue was discovered in Schneider Electric Wonderware InduSoft Web Studio v8.0 Patch 3 and prior versions. Upon installation, Wonderware InduSoft Web Studio creates a new directory and two files, which are placed in the system's path and can be manipulated by non-administrators. This could allow an authenticated user to escalate his or her privileges.
- Product
- Wonderware Indusoft Web Studio
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
May 18, 2017An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior.CVE-2017-7907 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.6
An Improper XML Parser Configuration issue was discovered in Schneider Electric Wonderware Historian Client 2014 R2 SP1 and prior. An improperly restricted XML parser (with improper restriction of XML external entity reference, or XXE) may allow an attacker to enter malicious input through the application which could cause a denial of service or disclose file contents from a server or connected network.
- Product
- Wonderware Historian Client
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsoftware.schneider-electric.comsecurityfocus.com
May 18, 2017A Command Injection issue was discovered in Satel Iberia SenNet Data Logger and Electricity Meters: SenNet Optimal DataLogger V5.37c-1.43c and prior, SenNet SolCVE-2017-6048 · Other software · Satel-iberia · reported by ics-cert@hq.dhs.govHigh 8.8
A Command Injection issue was discovered in Satel Iberia SenNet Data Logger and Electricity Meters: SenNet Optimal DataLogger V5.37c-1.43c and prior, SenNet Solar Datalogger V5.03-1.56a and prior, and SenNet Multitask Meter V5.21a-1.18b and prior. Successful exploitation of this vulnerability could result in the attacker breaking out of the jailed shell and gaining full access to the system.
- Product
- Sennet Multitask Meter
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
May 9, 2017All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 fiCVE-2017-7967 · Other software · Schneider Electric SE · reported by cybersecurity@se.comMedium 5.5
All versions of VAMPSET software produced by Schneider Electric, prior to V2.2.189, are susceptible to a memory corruption vulnerability when a corrupted vf2 file is used. This vulnerability causes the software to halt or not start when trying to open the corrupted file. This vulnerability occurs when fill settings are intentionally malformed and is opened in a standalone state, without connection to a protection relay. This attack is not considered to be remotely exploitable. This vulnerability has no effect on the operation of the protection relay to which VAMPSET is connected. As Windows operating system remains operational and VAMPSET responds, it is able to be shut down through its normal closing protocol.
- Product
- VAMPSET
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordschneider-electric.comsecurityfocus.com
Apr 30, 2017Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitiveCVE-2017-8371 · Other software · Schneider-electric · reported by MITREMedium 6.8
Schneider Electric StruxureWare Data Center Expert before 7.4.0 uses cleartext RAM storage for passwords, which might allow remote attackers to obtain sensitive information via unspecified vectors.
- Product
- Struxureware Data Center Expert
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comdatacenterdynamics.com
Apr 20, 2017An Inadequate Encryption Strength issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior.CVE-2017-5160 · Other software · Aveva · reported by ics-cert@hq.dhs.govMedium 5.3
An Inadequate Encryption Strength issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The software will connect via Transport Layer Security without verifying the peer's SSL certificate properly.
- Product
- Wonderware Intouch Access Anywhere
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsoftware.schneider-electric.comsecurityfocus.com
Apr 20, 2017An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior.CVE-2017-5158 · Other software · Aveva · reported by ics-cert@hq.dhs.govCritical 9.8
An Information Exposure issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. Credentials may be exposed to external systems via specific URL parameters, as arbitrary destination addresses may be specified.
- Product
- Wonderware Intouch Access Anywhere
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsoftware.schneider-electric.comsecurityfocus.com
Apr 20, 2017A Cross-Site Request Forgery issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior.CVE-2017-5156 · Other software · Aveva · reported by ics-cert@hq.dhs.govHigh 8.8
A Cross-Site Request Forgery issue was discovered in Schneider Electric Wonderware InTouch Access Anywhere, version 11.5.2 and prior. The client request may be forged from a different site. This will allow an external site to access internal RDP systems on behalf of the currently logged in user.
- Product
- Wonderware Intouch Access Anywhere
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsoftware.schneider-electric.comsecurityfocus.com
Apr 11, 2017A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.CVE-2017-7689 · Other software · Schneider-electric · reported by MITRECritical 9.8
A Command Injection vulnerability in Schneider Electric homeLYnk Controller exists in all versions before 1.5.0.
- Product
- Homelynk Controller Lss100100 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
Apr 7, 2017A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions.CVE-2017-6033 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.8
A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path.
- Product
- Interactive Graphical Scada System
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
Apr 7, 2017An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830.CVE-2017-6019 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.5
An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.
- Product
- Conext Combox 865-1058 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
Apr 6, 2017Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\CVE-2017-7575 · Other software · Schneider-electric · reported by MITRECritical 9.8
Schneider Electric Modicon TM221CE16R 1.3.3.3 devices allow remote attackers to discover the application-protection password via a \x00\x01\x00\x00\x00\x05\x01\x5a\x00\x03\x00 request to the Modbus port (502/tcp). Subsequently the application may be arbitrarily downloaded, modified, and uploaded.
- Product
- Modicon Tm221ce16r Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
Apr 6, 2017Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability.CVE-2017-7574 · Other software · Schneider-electric · reported by MITRECritical 9.8
Schneider Electric SoMachine Basic 1.4 SP1 and Schneider Electric Modicon TM221CE16R 1.3.3.3 devices have a hardcoded-key vulnerability. The Project Protection feature is used to prevent unauthorized users from opening an XML protected project file, by prompting the user for a password. This XML file is AES-CBC encrypted; however, the key used for encryption (SoMachineBasicSoMachineBasicSoMa) cannot be changed. After decrypting the XML file with this key, the user password can be found in the decrypted data. After reading the user password, the project can be opened and modified with the Schneider product.
- Product
- Modicon Tm221ce16r Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
Mar 8, 2017An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior.CVE-2017-5178 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered in Schneider Electric Tableau Server/Desktop Versions 7.0 to 10.1.3 in Wonderware Intelligence Versions 2014R3 and prior. These versions contain a system account that is installed by default. The default system account is difficult to configure with non-default credentials after installation, and changing the default credentials in the embedded Tableau Server is not documented. If Tableau Server is used with Windows integrated security (Active Directory), the software is not vulnerable. However, when Tableau Server is used with local authentication mode, the software is vulnerable. The default system account could be used to gain unauthorized access.
- Product
- Tableau Desktop
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsoftware.schneider-electric.comsecurityfocus.com
Feb 13, 2017An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter.CVE-2017-5167 · Other software · Binom3 · reported by ics-cert@hq.dhs.govHigh 8.6
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Users do not have any option to change their own passwords.
- Product
- Universal Multifunctional Electric Power Quality Meter Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter.CVE-2017-5166 · Other software · Binom3 · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. An INFORMATION EXPOSURE flaw can be used to gain privileged access to the device.
- Product
- Universal Multifunctional Electric Power Quality Meter Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter.CVE-2017-5165 · Other software · Binom3 · reported by ics-cert@hq.dhs.govHigh 7.6
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. There is no CSRF Token generated per page and/or per (sensitive) function. Successful exploitation of this vulnerability can allow silent execution of unauthorized actions on the device such as configuration parameter changes, and saving modified configuration.
- Product
- Universal Multifunctional Electric Power Quality Meter Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter.CVE-2017-5164 · Other software · Binom3 · reported by ics-cert@hq.dhs.govMedium 6.1
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Input sent from a malicious client is not properly verified by the server. An attacker can execute arbitrary script code in another user's browser session (CROSS-SITE SCRIPTING).
- Product
- Universal Multifunctional Electric Power Quality Meter Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter.CVE-2017-5162 · Other software · Binom3 · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered in BINOM3 Universal Multifunctional Electric Power Quality Meter. Lack of authentication for remote service gives access to application set up and configuration.
- Product
- Universal Multifunctional Electric Power Quality Meter Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0.CVE-2017-5157 · Other software · Schneider Electric · reported by ics-cert@hq.dhs.govMedium 6.1
An issue was discovered in Schneider Electric homeLYnk Controller, LSS100100, all versions prior to V1.5.0. The homeLYnk controller is susceptible to a cross-site scripting attack. User inputs can be manipulated to cause execution of JavaScript code.
- Product
- Homelynk Controller Lss100100 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier.CVE-2017-5155 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.3
An issue was discovered in Schneider Electric Wonderware Historian 2014 R2 SP1 P01 and earlier. Wonderware Historian creates logins with default passwords, which can allow a malicious entity to compromise Historian databases. In some installation scenarios, resources beyond those created by Wonderware Historian may be compromised as well.
- Product
- Wonderware Historian
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsoftware.schneider-electric.comsecurityfocus.com
Feb 13, 2017An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prioCVE-2016-9360 · Other software · GE · reported by ics-cert@hq.dhs.govMedium 6.7
An issue was discovered in General Electric (GE) Proficy HMI/SCADA iFIX Version 5.8 SIM 13 and prior versions, Proficy HMI/SCADA CIMPLICITY Version 9.0 and prior versions, and Proficy Historian Version 6.0 and prior versions. An attacker may be able to retrieve user passwords if he or she has access to an authenticated session.
- Product
- Cimplicity
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comsecuritytracker.com
Feb 13, 2017An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis CVE-2016-8374 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.5
An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker may be able to disrupt a targeted web server, resulting in a denial of service because of UNCONTROLLED RESOURCE CONSUMPTION.
- Product
- Magelis GTU Universal Panel Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJCVE-2016-8370 · Other software · Mitsubishielectric · reported by ics-cert@hq.dhs.govHigh 7.5
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.
- Product
- Qj71e71-100 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJCVE-2016-8368 · Other software · Mitsubishielectric · reported by ics-cert@hq.dhs.govHigh 8.6
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.
- Product
- Qj71e71-100 Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis CVE-2016-8367 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 5.3
An issue was discovered in Schneider Electric Magelis HMI Magelis GTO Advanced Optimum Panels, all versions, Magelis GTU Universal Panel, all versions, Magelis STO5xx and STU Small panels, all versions, Magelis XBT GH Advanced Hand-held Panels, all versions, Magelis XBT GK Advanced Touchscreen Panels with Keyboard, all versions, Magelis XBT GT Advanced Touchscreen Panels, all versions, and Magelis XBT GTW Advanced Open Touchscreen Panels (Windows XPe). An attacker can open multiple connections to a targeted web server and keep connections open preventing new connections from being made, rendering the web server unavailable during an attack.
- Product
- Magelis GTU Universal Panel Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Schneider Electric Unity PRO prior to V11.1.CVE-2016-8354 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7
An issue was discovered in Schneider Electric Unity PRO prior to V11.1. Unity projects can be compiled as x86 instructions and loaded onto the PLC Simulator delivered with Unity PRO. These x86 instructions are subsequently executed directly by the simulator. A specially crafted patched Unity project file can make the simulator execute malicious code by redirecting the control flow of these instructions.
- Product
- Unity Pro
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFECCVE-2016-8352 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govCritical 10
An issue was discovered in Schneider Electric ConneXium firewalls TCSEFEC23F3F20 all versions, TCSEFEC23F3F21 all versions, TCSEFEC23FCF20 all versions, TCSEFEC23FCF21 all versions, and TCSEFEC2CF3F20 all versions. A stack-based buffer overflow can be triggered during the SNMP login authentication process that may allow an attacker to remotely execute code.
- Product
- Connexium Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older.CVE-2016-5818 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered in Schneider Electric PowerLogic PM8ECC device 2.651 and older. Undocumented hard-coded credentials allow access to the device.
- Product
- Powerlogic Pm8ecc Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PMCVE-2016-5815 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govCritical 9.8
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. No authentication is configured by default. An unauthorized user can access the device management portal and make configuration changes.
- Product
- Ion5000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Feb 13, 2017An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PMCVE-2016-5809 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 8.8
An issue was discovered on Schneider Electric IONXXXX series power meters ION73XX series, ION75XX series, ION76XX series, ION8650 series, ION8800 series, and PM5XXX series. There is no CSRF Token generated to authenticate the user during a session. Successful exploitation of this vulnerability can allow unauthorized configuration changes to be made and saved.
- Product
- Ion5000
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Nov 24, 2016General Electric (GE) Bently Nevada 3500/22M USB with firmware before 5.0 and Bently Nevada 3500/22M Serial have open ports, which makes it easier for remote atCVE-2016-5788 · Other software · GE · reported by ics-cert@hq.dhs.govCritical 10
General Electric (GE) Bently Nevada 3500/22M USB with firmware before 5.0 and Bently Nevada 3500/22M Serial have open ports, which makes it easier for remote attackers to obtain privileged access via unspecified vectors.
- Product
- Bently Nevada 3500/22m USB Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comics-cert.us-cert.gov
Jul 15, 2016General Electric (GE) Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuratCVE-2016-5787 · Other software · GE · reported by ics-cert@hq.dhs.govMedium 6.3
General Electric (GE) Digital Proficy HMI/SCADA - CIMPLICITY before 8.2 SIM 27 mishandles service DACLs, which allows local users to modify a service configuration via unspecified vectors.
- Product
- Cimplicity
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordsecurityfocus.comge-ip.force.com
Jul 15, 2016An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execuCVE-2016-4529 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.3
An unspecified ActiveX control in Schneider Electric SoMachine HVAC Programming Software for M171/M172 Controllers before 2.1.0 allows remote attackers to execute arbitrary code via unknown vectors, related to the INTERFACESAFE_FOR_UNTRUSTED_CALLER (aka safe for scripting) flag.
- Product
- Somachine Hvac Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
Jul 15, 2016Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain accCVE-2016-4520 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govCritical 9.8
Schneider Electric Pelco Digital Sentry Video Management System with firmware before 7.14 has hardcoded credentials, which allows remote attackers to obtain access, and consequently execute arbitrary code, via unspecified vectors.
- Product
- Pelco Digital Sentry Video Management System Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordschneider-electric.comsecurityfocus.com
Jun 25, 2016Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to iCVE-2016-4513 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.1
Cross-site scripting (XSS) vulnerability in the Schneider Electric PowerLogic PM8ECC module before 2.651 for PowerMeter 800 devices allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
- Product
- Powerlogic Pm8ecc Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Jun 9, 2016General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware beforCVE-2016-2310 · Other software · GE · reported by ics-cert@hq.dhs.govCritical 9.8
General Electric (GE) Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware before 5.5.0 and ML810, ML3000, and ML3100 switches with firmware before 5.5.0k have hardcoded credentials, which allows remote attackers to modify configuration settings via the web interface.
- Product
- Multilink Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Apr 6, 2016Stack-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allCVE-2016-2292 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.5
Stack-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors.
- Product
- Proface Gp-pro EX Ex-ed
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Apr 6, 2016Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute CVE-2016-2291 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 6.5
Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allow remote attackers to execute arbitrary code or cause a denial of service (out-of-bounds read) via unspecified vectors.
- Product
- Proface Gp-pro EX Ex-ed
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Apr 6, 2016Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 alloCVE-2016-2290 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 8.8
Heap-based buffer overflow in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 allows remote attackers to execute arbitrary code via unspecified vectors.
- Product
- Proface Gp-pro EX Ex-ed
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Apr 6, 2016The FTP server in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 has hardcoded crCVE-2015-7921 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govCritical 9.1
The FTP server in Pro-face GP-Pro EX EX-ED before 4.05.000, PFXEXEDV before 4.05.000, PFXEXEDLS before 4.05.000, and PFXEXGRPLS before 4.05.000 has hardcoded credentials, which makes it easier for remote attackers to bypass authentication by leveraging knowledge of these credentials.
- Product
- Proface Gp-pro EX Ex-ed
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Mar 11, 2016Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs wCVE-2015-6485 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govMedium 5.3
Schneider Electric Telvent Sage 2300 RTUs with firmware before C3413-500-S01, and LANDAC II-2, Sage 1410, Sage 1430, Sage 1450, Sage 2400, and Sage 3030M RTUs with firmware before C3414-500-S02J2, allow remote attackers to obtain sensitive information from device memory by reading a padding field of an Ethernet packet.
- Product
- Telvent RTU Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordics-cert.us-cert.govics-cert.us-cert.gov
Mar 2, 2016Schneider Electric Struxureware Building Operations Automation Server AS 1.7 and earlier and AS-P 1.7 and earlier allows remote authenticated administrators to CVE-2016-2278 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 7.2
Schneider Electric Struxureware Building Operations Automation Server AS 1.7 and earlier and AS-P 1.7 and earlier allows remote authenticated administrators to execute arbitrary OS commands by defeating an msh (aka Minimal Shell) protection mechanism.
- Product
- Struxureware Building Operations Automation Server AS Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comics-cert.us-cert.gov
Feb 5, 2016General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to obtain sensitive cleartext CVE-2016-0862 · Other software · GE · reported by ics-cert@hq.dhs.govMedium 6.5
General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to obtain sensitive cleartext account information via unspecified vectors.
- Product
- Snmp/web Adapter Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordapps.geindustrial.compacketstormsecurity.com
Feb 5, 2016General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands CVE-2016-0861 · Other software · GE · reported by ics-cert@hq.dhs.govHigh 8.8
General Electric (GE) Industrial Solutions UPS SNMP/Web Adapter devices with firmware before 4.8 allow remote authenticated users to execute arbitrary commands via unspecified vectors.
- Product
- UPS Snmp Web Adapter Firmware
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recordapps.geindustrial.compacketstormsecurity.com
Dec 21, 2015Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitraCVE-2015-7937 · Other software · Schneider-electric · reported by ics-cert@hq.dhs.govHigh 10
Stack-based buffer overflow in the GoAhead Web Server on Schneider Electric Modicon M340 PLC BMXNOx and BMXPx devices allows remote attackers to execute arbitrary code via a long password in HTTP Basic Authentication data.
- Product
- Bmxnoc0401
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comsecurityfocus.com
Dec 15, 2015The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of sCVE-2015-8561 · Other software · Schneider-electric · reported by MITREMedium 6.8
The F1BookView ActiveX control in F1 Bookview in Schneider Electric ProClima before 6.2 allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption) via a crafted integer value to the (1) AttachToSS, (2) CopyAll, (3) CopyRange, (4) CopyRangeEx, or (5) SwapTable method, a different vulnerability than CVE-2015-7918.
- Product
- Proclima
- What to do
- Apply the vendor’s update. The NVD record links to the advisory.
Full record and what to do →NVD recorddownload.schneider-electric.comzerodayinitiative.com
Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.
Tell us what you're building.
A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.
Not ready to talk yet? Run the free website check and see what Google sees.