59 results · page 2 of 2

  • Jul 2, 2019Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service.CVE-2017-11580 · Other software · Blipcare · reported by MITREMedium 6.5

    Blipcare Wifi blood pressure monitor BP700 10.1 devices allow memory corruption that results in Denial of Service. When connected to the "Blip" open wireless connection provided by the device, if a large string is sent as a part of the HTTP request in any part of the HTTP headers, the device could become completely unresponsive. Presumably this happens as the memory footprint provided to this device is very small. According to the specs from Rezolt, the Wi-Fi module only has 256k of memory. As a result, an incorrect string copy operation using either memcpy, strcpy, or any of their other variants could result in filling up the memory space allocated to the function executing and this would result in memory corruption. To test the theory, one can modify the demo application provided by the Cypress WICED SDK and introduce an incorrect "memcpy" operation and use the compiled application on the evaluation board provided by Cypress semiconductors with exactly the same Wi-Fi SOC. The results were identical where the device would completely stop responding to any of the ping or web requests.

    Product
    Wi-fi Blood Pressure Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 2, 2019In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device.CVE-2017-11579 · Other software · Blipcare · reported by MITREHigh 7.1

    In the most recent firmware for Blipcare, the device provides an open Wireless network called "Blip" for communicating with the device. The user connects to this open Wireless network and uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is in vicinity of Wireless signal generated by the Blipcare device to easily sniff the credentials. Also, an attacker can connect to the open wireless network "Blip" exposed by the device and modify the HTTP response presented to the user by the device to execute other attacks such as convincing the user to download and execute a malicious binary that would infect a user's computer or mobile device with malware.

    Product
    Wi-fi Blood Pressure Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 2, 2019It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management iCVE-2017-11578 · Other software · Blipcare · reported by MITREMedium 5.9

    It was discovered as a part of the research on IoT devices in the most recent firmware for Blipcare device that the device allows to connect to web management interface on a non-SSL connection using plain text HTTP protocol. The user uses the web management interface of the device to provide the user's Wi-Fi credentials so that the device can connect to it and have Internet access. This device acts as a Wireless Blood pressure monitor and is used to measure blood pressure levels of a person. This allows an attacker who is connected to the Blipcare's device wireless network to easily sniff these values using a MITM attack.

    Product
    Wi-fi Blood Pressure Monitor Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 28, 2019Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters,CVE-2019-10964 · Other software · Medtronic · reported by ics-cert@hq.dhs.govHigh 7.1

    Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, and CareLink USB devices. This wireless RF communication protocol does not properly implement authentication or authorization. An attacker with adjacent access to one of the affected insulin pump models can inject, replay, modify, and/or intercept data. This vulnerability could also allow attackers to change pump settings and control insulin delivery.

    Product
    MiniMed 508 pump
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 22, 2019FreeRADIUS before 3.0.19 does not prevent use of reflection for authentication spoofing, aka a "Dragonblood" issue, a similar issue to CVE-2019-9497.CVE-2019-11234 · Other software · Freeradius · reported by MITRECritical 9.8

    FreeRADIUS before 3.0.19 does not prevent use of reflection for authentication spoofing, aka a "Dragonblood" issue, a similar issue to CVE-2019-9497.

    Product
    Freeradius
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 5, 2017The Everyday Health Diabetes in Check: Blood Glucose & Carb Tracker app 3.4.2 for iOS does not verify X.509 certificates from SSL servers, which allows man-in-tCVE-2017-5906 · Other software · Everyday Health INC · reported by MITREMedium 5.9

    The Everyday Health Diabetes in Check: Blood Glucose & Carb Tracker app 3.4.2 for iOS does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.

    Product
    Diabetes IN Check\
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Oct 20, 2014The Blood (aka com.sheridan.ash) application 2.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spCVE-2014-7543 · Other software · Bloodjournal · reported by cret@cert.orgMedium 5.4

    The Blood (aka com.sheridan.ash) application 2.1 for Android does not verify X.509 certificates from SSL servers, which allows man-in-the-middle attackers to spoof servers and obtain sensitive information via a crafted certificate.

    Product
    Blood
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 31, 2007Stack-based buffer overflow in Bloodshed Dev-C++ 4.9.9.2 allows user-assisted remote attackers to cause a denial of service (application crash) and possibly exeCVE-2007-0643 · Other software · Bloodshed Software · reported by MITREMedium 4.3

    Stack-based buffer overflow in Bloodshed Dev-C++ 4.9.9.2 allows user-assisted remote attackers to cause a denial of service (application crash) and possibly execute arbitrary code via a long line in a .cpp file.

    Product
    Dev-c++
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 31, 2004Buffer overflow in Monolith games including (1) Alien versus Predator 2 1.0.9.6 and earlier, (2) Blood 2 2.1 and earlier, (3) No one lives forever 1.004 and earCVE-2004-1587 · Other software · Monolith Productions · reported by MITREMedium 5

    Buffer overflow in Monolith games including (1) Alien versus Predator 2 1.0.9.6 and earlier, (2) Blood 2 2.1 and earlier, (3) No one lives forever 1.004 and earlier and (4) Shogo 2.2 and earlier allows remote attackers to cause a denial of service (application crash) via a long secure Gamespy query.

    Product
    Alien Versus Predator
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.