Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 45 min ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,766exploited flaws on CISA’s list
35added in the last 30 days
575new WordPress flaws this week
391,358entries in the database

1,389 results · page 17 of 28

  • May 26, 2021Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized acCVE-2021-22738 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access when credentials are discovered after a brute force attack.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of whenCVE-2021-22737 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior whCVE-2021-22736 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a denial of service when an unauthorized file is uploaded.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code exeCVE-2021-22735 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.2

    Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code execution when unauthorized code is copied to the device.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Verification of Cryptographic Signature vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause remote code exCVE-2021-22734 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.2

    Improper Verification of Cryptographic Signature vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause remote code execution when an attacker loads unauthorized code.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized coCVE-2021-22733 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized code is loaded into the system folder.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a code execution issue when an atCVE-2021-22732 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a code execution issue when an attacker loads unauthorized code on the web server.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an CVE-2021-22731 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an unauthorized password change through HTTP / HTTPS when basic user information is known by a remote attacker.

    Product
    Mcsesp083f23g0 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to systemCVE-2021-22705 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert

    Product
    Vijeo Designer
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specifiCVE-2021-22699 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    Improper Input Validation vulnerability exists in Modicon M241/M251 logic controllers firmware prior to V5.1.9.1 that could cause denial of service when specific crafted requests are sent to the controller over HTTP.

    Product
    Modicon M241 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 22, 2021Improper authentication vulnerability in GOT2000 series GT27 model VNC server versions 01.39.010 and prior, GOT2000 series GT25 model VNC server versions 01.39.CVE-2021-20590 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 7.5

    Improper authentication vulnerability in GOT2000 series GT27 model VNC server versions 01.39.010 and prior, GOT2000 series GT25 model VNC server versions 01.39.010 and prior, GOT2000 series GT21 model GT2107-WTBD VNC server versions 01.40.000 and prior, GOT2000 series GT21 model GT2107-WTSD VNC server versions 01.40.000 and prior, GOT SIMPLE series GS21 model GS2110-WTBD-N VNC server versions 01.40.000 and prior and GOT SIMPLE series GS21 model GS2107-WTBD-N VNC server versions 01.40.000 and prior allows a remote unauthenticated attacker to gain unauthorized access via specially crafted packets when the "VNC server" function is used.

    Product
    Got2000 Gt27 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2021A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could alCVE-2021-22720 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.2

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring a project.

    Product
    C-bus Toolkit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2021A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could alCVE-2021-22719 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 8.8

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when a file is uploaded.

    Product
    C-bus Toolkit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2021A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could alCVE-2021-22718 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when restoring project files.

    Product
    C-bus Toolkit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2021A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could alCVE-2021-22717 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 8.8

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in C-Bus Toolkit (V1.15.7 and prior) that could allow a remote code execution when processing config files.

    Product
    C-bus Toolkit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Apr 13, 2021A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies CVE-2021-22716 · Other software · Schneider Electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could allow remote code execution when an unprivileged user modifies a file. Affected Product: C-Bus Toolkit (V1.15.9 and prior)

    Product
    C-Bus Toolkit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2021A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions pCVE-2021-22714 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions prior to V3.0.0), which could cause the meter to reboot or allow for remote code execution.

    Product
    Powerlogic Ion7400 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2021A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, anCVE-2021-22713 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION8650, ION8800, ION7650, ION7700/73xx, and ION83xx/84xx/85xx/8600 (see security notifcation for affected versions), which could cause the meter to reboot.

    Product
    Powerlogic Ion8650 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2021A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (CVE-2021-22712 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to an unchecked pointer address.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2021A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (CVE-2021-22711 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in arbitrary read or write conditions when malicious CGF (Configuration Group File) file is imported to IGSS Definition due to missing validation of input data.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2021A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (CVE-2021-22710 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could cause remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Mar 11, 2021A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (CVE-2021-22709 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-119:Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists in Interactive Graphical SCADA System (IGSS) Definition (Def.exe) V15.0.0.21041 and prior, which could result in loss of data or remote code execution when malicious CGF (Configuration Group File) file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 19, 2021Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versionsCVE-2021-20588 · Other software · Mitsubishi Electric Corporation · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 7.5

    Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MEL

    Product
    CPU Module Logging Configuration Tool
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 19, 2021Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW ConCVE-2021-20587 · Other software · Mitsubishi Electric Corporation · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 7.5

    Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT SoftGOT1000 Version3 versions 3.245F and prior, GT SoftGOT2000 Version1 versions 1.250L and prior, GX Configurator-DP versions 7.14Q and prior, GX Configurator-QP all versions, GX Developer versions 8.506C and prior, GX Explorer all versions, GX IEC Developer all versions, GX LogViewer versions 1.115U and prior, GX RemoteService-I all versions, GX Works2 versions 1.597X and prior, GX Works3 versions 1.070Y and prior, iQ Monozukuri ANDON (Data Transfer) versions 1.003D and prior, iQ Monozukuri Process Remote Monitoring (Data Transfer) versions 1.002C and prior, M_CommDTM-HART all versions, M_CommDTM-IO-Link versions 1.03D and prior, MELFA-Works versions 4.4 and prior, MELSEC WinCPU Setting Utilit

    Product
    CPU Module Logging Configuration Tool
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 19, 2021The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arCVE-2020-25171 · Other software · Fuji Electric · reported by ics-cert@hq.dhs.govHigh 7.8

    The affected Fuji Electric V-Server Lite versions prior to 3.3.24.0 are vulnerable to an out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.

    Product
    V-Server Lite
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 19, 2021A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION900CVE-2021-22703 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts HTTP network traffic between a user and the device.

    Product
    Powerlogic Ion7400 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 19, 2021A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ICVE-2021-22702 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device.

    Product
    Powerlogic Ion7400 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 19, 2021A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notiCVE-2021-22701 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 4.5

    A CWE-352: Cross-Site Request Forgery vulnerability exists in PowerLogic ION7400, ION7650, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause a user to perform an unintended action on the target device when using the HTTP web interface.

    Product
    Powerlogic Ion7400 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2021In Electric Coin Company Zcashd before 2.1.1-1, the time offset between messages could be leveraged to obtain sensitive information about the relationship betweCVE-2020-8807 · Other software · Electriccoin · reported by MITREMedium 5.3

    In Electric Coin Company Zcashd before 2.1.1-1, the time offset between messages could be leveraged to obtain sensitive information about the relationship between a suspected victim's address and an IP address, aka a timing side channel.

    Product
    Zcashd
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Feb 5, 2021Electric Coin Company Zcashd before 2.1.1-1 allows attackers to trigger consensus failure and double spending.CVE-2020-8806 · Other software · Electriccoin · reported by MITREHigh 7.5

    Electric Coin Company Zcashd before 2.1.1-1 allows attackers to trigger consensus failure and double spending. A valid chain could be incorrectly rejected because timestamp requirements on block headers were not properly enforced.

    Product
    Zcashd
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 29, 2021Resource management errors vulnerability in a robot controller of MELFA FR Series(controller "CR800-*V*D" of RV-*FR***-D-* all versions, controller "CR800-*HD" CVE-2021-20586 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 7.5

    Resource management errors vulnerability in a robot controller of MELFA FR Series(controller "CR800-*V*D" of RV-*FR***-D-* all versions, controller "CR800-*HD" of RH-*FRH***-D-* all versions, controller "CR800-*HRD" of RH-*FRHR***-D-* all versions, controller "CR800-*V*R with R16RTCPU" of RV-*FR***-R-* all versions, controller "CR800-*HR with R16RTCPU" of RH-*FRH***-R-* all versions, controller "CR800-*HRR with R16RTCPU" of RH-*FRHR***-R-* all versions, controller "CR800-*V*Q with Q172DSRCPU" of RV-*FR***-Q-* all versions, controller "CR800-*HQ with Q172DSRCPU" of RH-*FRH***-Q-* all versions, controller "CR800-*HRQ with Q172DSRCPU" of RH-*FRHR***-Q-* all versions) and a robot controller of MELFA CR Series(controller "CR800-CVD" of RV-8CRL-D-* all versions, controller "CR800-CHD" of RH-*CRH**-D-* all versions) as well as a cooperative robot ASSISTA(controller "CR800-05VD" of RV-5AS-D-* all versions) allows a remote unauthenticated attacker to cause a DoS of the execution of the robot program and the Ethernet communication by sending a large amount of packets in burst over a short period of time. As a result of DoS, an error may occur. A reset is required to recover it if the error o

    Product
    Rv2fr Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2021Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project fileCVE-2021-22655 · Other software · Fujielectric · reported by ics-cert@hq.dhs.govHigh 7.8

    Multiple out-of-bounds read issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).

    Product
    V-server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2021Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project filCVE-2021-22653 · Other software · Fujielectric · reported by ics-cert@hq.dhs.govHigh 7.8

    Multiple out-of-bounds write issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).

    Product
    V-server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2021A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file CVE-2021-22641 · Other software · Fujielectric · reported by ics-cert@hq.dhs.govHigh 7.8

    A heap-based buffer overflow issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).

    Product
    V-server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2021An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file thatCVE-2021-22639 · Other software · Fujielectric · reported by ics-cert@hq.dhs.govHigh 7.8

    An uninitialized pointer issue has been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).

    Product
    V-server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 27, 2021Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special proCVE-2021-22637 · Other software · Fujielectric · reported by ics-cert@hq.dhs.govHigh 7.8

    Multiple stack-based buffer overflow issues have been identified in the way the application processes project files, allowing an attacker to craft a special project file that may allow arbitrary code execution on the Tellus Lite V-Simulator and V-Server Lite (versions prior to 4.0.10.0).

    Product
    V-server
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 26, 2021A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that couldCVE-2021-22698 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a stack-based buffer overflow to occur which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.

    Product
    Ecostruxure Power Build - Rapsody
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 26, 2021A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that couldCVE-2021-22697 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists in the EcoStruxure Power Build - Rapsody software (V2.1.13 and prior) that could allow a use-after-free condition which could result in remote code execution when a malicious SSD file is uploaded and improperly parsed.

    Product
    Ecostruxure Power Build - Rapsody
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jan 26, 2021A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that cCVE-2020-28221 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-20: Improper Input Validation vulnerability exists in EcoStruxure™ Operator Terminal Expert and Pro-face BLUE (version details in the notification) that could cause arbitrary code execution when the Ethernet Download feature is enable on the HMI.

    Product
    Ecostruxure Operator Terminal Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 13, 2020Improper check or handling of exceptional conditions in MELSEC iQ-F series FX5U(C) CPU unit firmware version 1.060 and earlier allows an attacker to cause a denCVE-2020-5665 · Other software · Mitsubishi Electric Corporation · reported by vultures@jpcert.or.jpHigh 7.4

    Improper check or handling of exceptional conditions in MELSEC iQ-F series FX5U(C) CPU unit firmware version 1.060 and earlier allows an attacker to cause a denial-of-service (DoS) condition on program execution and communication by sending a specially crafted ARP packet.

    Product
    MELSEC iQ-F series FX5U(C) CPU unit
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control ExpeCVE-2020-7560 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 8.6

    A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software.

    Product
    Ecostruxure Control Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and ModicoCVE-2020-7549 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.3

    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause denial of HTTP and FTP services when a series of specially crafted requests is sent to the controller over HTTP.

    Product
    Modicon M340 Bmxp341000 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & ModiconCVE-2020-7543 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.

    Product
    Modicon M580 Bmep584040 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & ModiconCVE-2020-7542 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.

    Product
    Modicon M580 Bmep584040 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and assoCVE-2020-7541 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.3

    A CWE-425: Direct Request ('Forced Browsing') vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of sensitive data when sending a specially crafted request to the controller over HTTP.

    Product
    Modicon M340 Bmxp341000 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon PremiuCVE-2020-7540 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.

    Product
    Modicon M340 Bmxp341000 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and ModiconCVE-2020-7539 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-754 Improper Check for Unusual or Exceptional Conditions vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause a denial of service vulnerability when a specially crafted packet is sent to the controller over HTTP.

    Product
    Modicon M340 Bmxp341000 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & ModiconCVE-2020-7537 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Legacy Controllers Modicon Quantum & Modicon Premium (see security notifications for affected versions), that could cause denial of service when a specially crafted Read Physical Memory request over Modbus is sent to the controller.

    Product
    Modicon M580 Bmep584040 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 CommunicCVE-2020-7536 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-754:Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M340 CPUs (BMXP34* versions prior to V3.30) Modicon M340 Communication Ethernet modules (BMXNOE0100 (H) versions prior to V3.4 BMXNOE0110 (H) versions prior to V6.6 BMXNOR0200H all versions), that could cause the device to be unreachable when modifying network parameters over SNMP.

    Product
    Modicon M340 Bmxp341000 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Dec 10, 2020A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M3CVE-2020-7535 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal' Vulnerability Type) vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause disclosure of information when sending a specially crafted request to the controller over HTTP.

    Product
    Modicon M340 Bmxp341000 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.