Critical security advisoryCriticalFlagged by our vulnerability database: PHP2Shell is on CISA’s exploited list. Most WordPress hosting runs PHP. See if your site is affectedFlagged by our vulnerability database: PHP2Shell is being exploited. DetailsExploited: PHP2Shell. Check your site
HuttenlocherTechnologies
Updated 12 h ago

Vulnerability database

Every flaw the U.S. government’s cybersecurity agency (CISA) has confirmed attackers are using, plus the new WordPress plugin and theme bugs published each day, sorted by what they mean for a small business. We refresh it twice a day. If you see something your website or office runs, tell us.

1,766exploited flaws on CISA’s list
35added in the last 30 days
570new WordPress flaws this week
391,310entries in the database

1,389 results · page 16 of 28

  • Jul 21, 2021A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitlCVE-2021-22770 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 6.5

    A CWE-200: Information Exposure vulnerability exists in Easergy T300 with firmware V2.7.1 and older that exposes sensitive information to an actor not explicitly authorized to have access to that information.

    Product
    Easergy T300 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVCVE-2021-22730 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 CVE-2021-22729 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized administrative privileges when accessing to the charging station web server.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2CVE-2021-22728 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 6.5

    A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause disclosure of encrypted credentials when consulting the maintenance report.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2CVE-2021-22727 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to gain unauthorized access to the charging station web server

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2CVE-2021-22726 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 8.1

    A CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to perform unintended actions or access to data when crafted malicious parameters are submitted to the charging station web server.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVCVE-2021-22723 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 6.1

    A CWE-79: Improper Neutralization of Input During Web Page Generation (Cross-siteScripting) through Cross-Site Request Forgery (CSRF) vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 CVE-2021-22722 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.4

    A CWE-79: Improper Neutralization of Input During Web Page Generation ('Stored Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could cause code injection when importing a CSV file or changing station parameters.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2CVE-2021-22721 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.3

    A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge of javascript code when crafted malicious parameters are submitted to the charging station web server.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlinkCVE-2021-22708 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.2

    A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to craft a malicious firmware package and bypass the signature verification mechanism.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVCVE-2021-22707 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 21, 2021A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all verCVE-2021-22706 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 6.1

    A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.

    Product
    Evlink City Evc1s22p4 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 14, 2021Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), CVE-2021-22782 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.5

    Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file.

    Product
    Ecostruxure Control Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 14, 2021Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), CVE-2021-22781 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.5

    Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.

    Product
    Ecostruxure Control Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 14, 2021Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), CVE-2021-22780 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.1

    Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.

    Product
    Ecostruxure Control Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 14, 2021Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoCVE-2021-22779 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.1

    Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.

    Product
    Ecostruxure Control Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 14, 2021Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), CVE-2021-22778 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.1

    Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.

    Product
    Ecostruxure Control Expert
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 13, 2021Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver.CVE-2021-20593 · Other software · Mitsubishi · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 7.1

    Incorrect Implementation of Authentication Algorithm in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.2.50 to Ver. 3.35, GB-50A Ver.2.50 to Ver. 3.35, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior) and Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) allows a remote authenticated attacker to impersonate administrators to disclose configuration information of the air conditioning system and tamper information (e.g. operation information and configuration of air conditioning system) by exploiting this vulnerability.

    Product
    G-50a Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jul 13, 2021Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and pCVE-2021-20595 · Other software · Mitsubishi · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 8.2

    Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets.

    Product
    G-50a Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or diCVE-2021-22769 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 4.3

    A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted.

    Product
    Easergy T300 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause dCVE-2021-22768 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767

    Product
    Powerlogic Egx100 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause dCVE-2021-22767 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276

    Product
    Powerlogic Egx100 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause dCVE-2021-22766 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.5

    A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet

    Product
    Powerlogic Egx100 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause dCVE-2021-22765 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet

    Product
    Powerlogic Egx100 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notificatCVE-2021-22764 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.3

    A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.

    Product
    Powerlogic Pm5560 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogiCVE-2021-22763 · Other software · Schneider-electric · reported by cybersecurity@se.comCritical 9.8

    A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.

    Product
    Powerlogic Pm5560 Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could resultCVE-2021-22762 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior thatCVE-2021-22761 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data orCVE-2021-22760 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution duCVE-2021-22759 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote CVE-2021-22758 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote CVE-2021-22757 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote CVE-2021-22756 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remoteCVE-2021-22755 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied data, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code executiCVE-2021-22754 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code executioCVE-2021-22753 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is being parsed by IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code executiCVE-2021-22752 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or executCVE-2021-22751 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code executiCVE-2021-22750 · Other software · Schneider-electric · reported by cybersecurity@se.comHigh 7.8

    A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.

    Product
    Interactive Graphical Scada System
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could causeCVE-2021-22749 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.3

    A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module.

    Product
    Modicon X80 Bmxnor0200h RTU Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • Jun 11, 2021Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all veCVE-2021-20591 · Other software · Mitsubishielectric · reported by Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jpHigh 7.5

    Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R series CPU modules (R00/01/02CPU all versions, R04/08/16/32/120(EN)CPU all versions, R08/16/32/120SFCPU all versions, R08/16/32/120PCPU all versions, R08/16/32/120PSFCPU all versions) allows a remote unauthenticated attacker to prevent legitimate clients from connecting to the MELSOFT transmission port (TCP/IP) by not closing a connection properly, which may lead to a denial of service (DoS) condition.

    Product
    R00cpu Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module CVE-2021-22747 · Other software · Schneider-electric · reported by cybersecurity@se.comLow 3.9

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746.

    Product
    Triconex Model 3009 MP Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module CVE-2021-22746 · Other software · Schneider-electric · reported by cybersecurity@se.comLow 3.9

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22747.

    Product
    Triconex Model 3009 MP Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module CVE-2021-22745 · Other software · Schneider-electric · reported by cybersecurity@se.comLow 3.9

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22746, and CVE-2021-22747.

    Product
    Triconex Model 3009 MP Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module CVE-2021-22744 · Other software · Schneider-electric · reported by cybersecurity@se.comLow 3.9

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22745, CVE-2021-22746, and CVE-2021-22747.

    Product
    Triconex Model 3009 MP Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reseCVE-2021-22743 · Other software · Schneider-electric · reported by cybersecurity@se.comLow 3.9

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.

    Product
    Triconex Model 3009 MP Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module CVE-2021-22742 · Other software · Schneider-electric · reported by cybersecurity@se.comLow 3.9

    Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.

    Product
    Triconex Model 3009 MP Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions),CVE-2021-22741 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 6.7

    Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions), and EcoStruxure Geo SCADA Expert 2020 (V83.7742.1 and prior), which could cause the revealing of account credentials when server database files are available. Exposure of these files to an attacker can make the system vulnerable to password decryption attacks. Note that “.sde” configuration export files do not contain user account password hashes.

    Product
    Clearscada
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorCVE-2021-22740 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 6.5

    Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.
  • May 26, 2021Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is firsCVE-2021-22739 · Other software · Schneider-electric · reported by cybersecurity@se.comMedium 5.9

    Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured.

    Product
    Spacelynk Firmware
    What to do
    Apply the vendor’s update. The NVD record links to the advisory.

Where this comes from: the exploited list is CISA’s Known Exploited Vulnerabilities catalog. Everything else is the whole National Vulnerability Database, where each record is published by the team that found the bug (Wordfence, Patchstack, WPScan, the vendors themselves and others); we show who. Exploit odds are FIRST’s EPSS, updated daily. Titles and categories are ours, so check the linked record before acting on a detail. For a write-up of the big ones, see our advisories. Every vendor, and every WordPress plugin and theme with a recorded flaw, also has its own page. All of it is free to reuse as JSON, CSV or RSS.

Weekly security brief

The flaws that hit local websites, every Friday.

One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.

Get in touch

Tell us what you're building.

A website, your marketing, a security check, an app, or the thing you've been running out of a spreadsheet for three years. A few lines is plenty.

01The person who'll do the work writes back
02A short call, then a written plan with the price
03Nothing starts until you say yes
04Hacked or down right now? Call, and we pick up the same day
843-331-6339

Not ready to talk yet? Run the free website check and see what Google sees.

What do you need?
Build
Grow
Protect
Urgent

No newsletter, no sales sequence. Just a reply.