By year
16
17
18
21
22
25
26
Bars are flaws published each year; the red part is the share attackers have used.
Latest high and critical flaws
- CVE-2026-89025 Hirschmann HiOS Switch Platform devices contain a denial-of-service vulnerability in the integrated web server due to missing validation of HTTP(S) content.High 8.7 · Sep 15, 2026
- CVE-2021-4477 Hirschmann HiLCOS OpenBAT and BAT450 products contain a firewall bypass vulnerability in IPv6 IPsec deployments that allows traffic from VPN connections to bypaCritical 9.3 · Apr 3, 2026
- CVE-2018-25236 Hirschmann HiOS and HiSecOS products RSP, RSPE, RSPS, RSPL, MSP, EES, EESX, GRS, OS, RED, EAGLE contain an authentication bypass vulnerability in the HTTP(S) maCritical 9.3 · Apr 3, 2026
- CVE-2017-20238 Hirschmann Industrial HiVision versions 06.0.00 and 07.0.00 prior to 06.0.06 and 07.0.01 contains an improper authorization vulnerability that allows read-only High 7.1 · Apr 3, 2026
- CVE-2017-20234 GarrettCom Magnum 6K and 10K managed switches contain an authentication bypass vulnerability that allows unauthenticated attackers to gain unauthorized access bCritical 9.3 · Apr 3, 2026
- CVE-2018-25237 Hirschmann HiSecOS devices versions prior to 05.3.03 contain a buffer overflow vulnerability in the HTTPS login interface when RADIUS authentication is enabled Critical 9.3 · Apr 3, 2026
- CVE-2016-15058 Hirschmann HiLCOS Classic Platform switches Classic L2E, L2P, L3E, L3P versions prior to 09.0.06 and Classic L2B prior to 05.3.07 contain a credential exposure High 8.6 · Apr 3, 2026
- CVE-2015-10148 Hirschmann HiLCOS devices OpenBAT, WLC, BAT300, BAT54 prior to 8.80 and OpenBAT prior to 9.10 are shipped with identical default SSH and SSL keys that cannot beHigh 8.8 · Apr 3, 2026
- CVE-2022-4987 Hirschmann Industrial HiVision version 08.1.03 prior to 08.1.04 and 08.2.00 contains a vulnerability in the execution of user-configured external applications tHigh 7 · Apr 3, 2026
- CVE-2020-37216 Hirschmann HiOS devices versions prior to 08.1.00 and 07.1.01 contain a denial of service vulnerability in the EtherNet/IP stack where improper handling of pacHigh 8.7 · Apr 3, 2026
- CVE-2017-20237 Hirschmann Industrial HiVision versions prior to 06.0.07 and 07.0.03 contains an authentication bypass vulnerability in the master service that allows unauthentCritical 9.3 · Apr 3, 2026
- CVE-2022-4986 Hirschmann EagleSDV version 05.4.01 prior to 05.4.02 contains a denial-of-service vulnerability that causes the device to crash during session establishment wheHigh 8.7 · Apr 2, 2026
- CVE-2025-15620 HiOS Switch Platform versions 09.1.00 through 09.4.04 and 10.0.00 through 10.3.00 contain a denial-of-service vulnerability in the web interface that allows remCritical 9.2 · Apr 2, 2026
- CVE-2024-14033 Hirschmann EagleSDV firmware prior to 05.4.02 contains a denial-of-service vulnerability in TLS session establishment.High 8.7 · Apr 2, 2026
- CVE-2024-14034 Hirschmann HiEOS devices versions prior to 01.1.00 contain an authentication bypass vulnerability in the HTTP(S) management module that allows unauthenticated rCritical 9.3 · Apr 2, 2026
- CVE-2023-7343 Hirschmann Industrial HiVision versions 05.0.00 through 08.3.01 prior to 08.3.02 contain an arbitrary code execution vulnerability triggered when an administratHigh 8.5 · Apr 2, 2026
- CVE-2023-7342 HiSecOS web server versions 03.4.00 prior to 04.1.00 contains a privilege escalation vulnerability that allows authenticated users with operator or auditor roleHigh 8.7 · Apr 2, 2026
- CVE-2023-53908 HiSecOS 04.0.01 contains a privilege escalation vulnerability that allows authenticated users to modify their access role through XML-based NETCONF configuratioHigh 8.7 · Dec 17, 2025
- CVE-2022-40282 The web server of Hirschmann BAT-C2 before 09.13.01.00R04 allows authenticated command injection.High 8.8 · Nov 25, 2022
- CVE-2021-30065 On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, crafted ModBus packeHigh 7.5 · Apr 3, 2022
- CVE-2021-30064 On Schneider Electric ConneXium Tofino Firewall TCSEFEA23F3F22 before 03.23, TCSEFEA23F3F20/21, and Belden Tofino Xenon Security Appliance, an SSH login can sucCritical 9.8 · Apr 3, 2022
- CVE-2021-30063 On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can cause an OPC enforcer High 7.5 · Apr 3, 2022
- CVE-2021-30062 On Schneider Electric ConneXium Tofino OPCLSM TCSEFM0000 before 03.23 and Belden Tofino Xenon Security Appliance, crafted OPC packets can bypass the OPC enforceHigh 7.5 · Apr 3, 2022
- CVE-2021-27734 Hirschmann HiOS 07.1.01, 07.1.02, and 08.1.00 through 08.5.xx and HiSecOS 03.3.00 through 03.5.01 allow remote attackers to change the credentials of existing uCritical 9.8 · May 17, 2021
- CVE-2018-5469 An Improper Restriction of Excessive Authentication Attempts issue was discovered in Belden Hirschmann RS, RSR, RSB, MACH100, MACH1000, MACH4000, MS, and OCTOPUCritical 9.8 · Mar 6, 2018
Part of our vulnerability database: the whole National Vulnerability Database plus CISA’s exploited list, refreshed twice a day. This is general guidance, not a review of your systems.
Weekly security brief
The flaws that hit local websites, every Friday.
One short email: what got exploited this week, which WordPress plugins broke, and what to check. Unsubscribe in one click.